background image

Water heater:

Set to deliver 140°F

water to the washer.

Laundry tub drain system:

Needs a 

20-gallon laundry tub. Top of tub
must be at least 34 inches high and
no higher than 72 inches from floor.

If a longer drain hose is needed,
drain hose (Part No. 388423) and
hose extension kit (Part No. 285442)
are available from a Whirlpool-
authorized parts distributor.

Dryer may be exhausted from the
rear or left or right side. Exhausting
through the side requires Part No.
279823. See “Exhaust requirements,”
Panels C and D.

Four-inch metal exhaust vent is
required.

SEE RECESSED AREA INSTRUCTIONS
ON PANEL G.

Important: Observe all
governing codes and
ordinances.

Check location where washer/dryer will
be installed. Proper installation is your
responsibility. The washer/dryer must not
be installed or stored in an area where it
will be exposed to water and/or
weather. Make sure you have
everything necessary for correct
installation.

Panel A

Location:

Should be large enough to

fully open dryer door to 90°. See Panel
G for “Recessed and closet installation
instructions” and “Product dimensions.”

Grounded electrical connection

is

required. See “Electrical requirements.”

Standpipe drain system:

Needs

a two-inch diameter standpipe
with minimum carry-away
capacity of 17 gallons per
minute. Top of standpipe must
be at least 34 inches high and
no higher than 72 inches from
floor.

Floor drain system

requires a

siphon break, Part No.
285320, available from a
Whirlpool-authorized
parts distributor.

Do Not store or operate washer/dryer
below 32°F (some water may remain in
washer). Proper operation of dryer
cycles requires temperatures above
45°F. See Use & Care Guide for
“Winterizing” information. 

Tools and materials

needed for installation:

Check code requirements:

Some codes

limit or do not permit installation of
clothes dryers in garages, closets,
mobile homes and sleeping quarters.
Contact your local building inspector.

Hot and cold water
faucets: 

Must be within

4 feet of the back of
the washer/dryer and
provide water pressure
of 5 -100 PSI.

Electrical requirements

A four-wire or three-wire, single-phase,
120/240-volt, 60-Hz, AC-only electrical
supply (or four-wire or three-wire,
120/208-volt, if specified on the
model/serial rating plate) is required on
a separate, 30-ampere circuit, fused on
both sides of the line. A time-delay fuse
or circuit breaker is recommended. The
model/serial rating plate is located in
the door well behind the dryer door on
the front of the opening.
It is the personal responsibility and
obligation of the customer to contact a
qualified electrician to assure that the
electrical installation is adequate and in
conformance with the National
Electrical Code, ANSI/NFPA 70 — latest
edition*, and all local codes and
ordinances.

Untape and
open washer
lid. Remove
packages
and hoses
from washer.

Drain hose
may also be
installed to a
laundry tub or
floor drain
system.
See Panel F.

level

Phillips screwdriver

pliers

utility
knife 

safety glasses

gloves

adjustable
wrench (two
may be
required)

flat-blade
screwdriver

Check utilities:

Proper, water and

electrical supply connections 

must

be

available.

Support:

Floor must be sturdy enough to

support washer/dryer weight, with water
and clothes, of 500 pounds.

Level floor:

1-inch maximum
slope under entire
washer/dryer.

Copies of the standards listed above may be
obtained from:

National Fire Protection Association 
Batterymarch Park
Quincy, Massachusetts 02269

Power supply cord

Local codes may permit the use of a
U.L.-listed, 120/240-volt minimum, 30-
ampere, dryer power supply cord kit
(pigtail). Power supply cord should be
Type SRD or SRDT and be at least four
feet long.  The wires that connect to the
dryer must end with ring terminals or
spade terminals with upturned ends.
A 3/4", U.L.-listed strain relief must be
installed where the power supply cord
connects to the dryer (see Figures 1 
and 2).

Four-wire power supply cord

NEMA 14-30P

Figure 1

NEUTRAL

NEUTRAL 

(white or center)

3/4" U.L.-listed
strain relief

This blade connected
to this conductor. 

ring terminals

spade
terminals with
upturned ends

spade
terminals with
upturned ends

Three-wire power supply cord

NEMA 10-30P

Figure 2

NEUTRAL

NEUTRAL 

(white)

3/4" U.L.-listed
strain relief

ground prong

ground wire
(green)

ring
terminals

WARNING

Explosion Hazard

Keep flammable materials and vapors,
such as gasoline, away from dryer.

Failure to do so can result in death,
explosion, or fire.

Your safety and the safety of others are

very important.

We have provided many important safety messages
in this manual and on your appliance. Always read
and obey all safety messages.

This is the safety alert symbol. 
This symbol alerts you to potential
hazards that can kill or hurt you and
others. 

All safety messages will follow the safety alert
symbol and either the word “DANGER” or
“WARNING”. These words mean:

All safety messages will tell you what the potential
hazard is, tell you how to reduce the chance of
injury, and tell you what can happen if the
instructions are not followed.

You can be killed or seriously injured if you
don’t immediately follow instructions.

You can be killed or seriously injured if you don’t
follow instructions.

WARNING

Before you start...

DANGER

Electrical Shock Hazard

Plug into a grounded 4-prong outlet.
Failure to do so can result in death or
electrical shock.

WARNING

Содержание 3397616

Страница 1: ...4 Controls are set in a running or ON position If you need assistance The Whirlpool Customer Interaction Center will answer any questions about operating or maintaining your washer dryer not covered in the Installation Instructions The Whirlpool Customer Interaction Center is open 24 hours a day 7 days a week Just dial 1 800 253 1301 the call is free When you call you will need the washer dryer mo...

Страница 2: ...ified electrician to assure that the electrical installation is adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances Untape and open washer lid Remove packages and hoses from washer Drain hose may also be installed to a laundry tub or floor drain system See Panel F level Phillips screwdriver pliers utility knife safety glasses...

Страница 3: ... wire connection A DIRECT WIRE 1 Disconnect the power supply 2 Remove terminal block cover 3 Strip 5 inches of outer covering from end of cable Leave bare ground wire at 5 inches Cut 1 1 2 inches from 3 remaining insulated wires Strip insulation back 1 inch see Figure 6 3 4 U L listed strain relief red white black to disconnect box NEUTRAL 10 gauge 3 wire with ground wire Romex Direct wire prepara...

Страница 4: ...tape screws or other fastening devices that extend into the interior of the vent to secure vent Service check Back pressure in any exhaust system used must not exceed 0 6 inches in water column measured with an incline manometer at the point that exhaust vent connects to dryer Direct wire preparation Figure 9 10 gauge 3 wire or 10 gauge 3 wire with ground wire Romex 3 4 U L listed strain relief Ba...

Страница 5: ... of the drain hose 3 While holding clamp open work end of drain hose onto drain connector 4 Position clamp over the drain hose area marked clamp Release clamp Clamp should be 1 4 inch from end of drain hose Save the shipping strap for use in Step 18 Pull the shipping strap completely out of the washer drain hose connector clamp drain hose 1 4 1 4 max cotter pins drain hose clamp yellow clamp Panel...

Страница 6: ...t marker 14 Attach bottom inlet hose inlet marked H to hot water faucet Attach top inlet hose inlet marked C to cold water faucet Tighten couplings to the faucets by hand Use pliers to make final two thirds turn Move washer dryer to its permanent location Remove cardboard hardboard from under washer dryer 15 Carefully move the washer dryer into final position Tilt washer dryer forward raising back...

Страница 7: ... B C strap strap 19 Put hook end of drain hose in laundry tub or standpipe Tightly wrap the shipping strap around the drain hose and laundry tub or standpipe as shown in Figures A and B Push plug into the nearest hole in the shipping strap If the water inlet faucets and drain standpipe are recessed put hook end of drain hose in standpipe Tightly wrap the shipping strap around the drain hose and fa...

Страница 8: ... 1 2 recess width 5 recess depth 27 cold water inlet exhaust outlet 36 3 4 28 1 2 drain outlet 22 3 4 0 WARNING To reduce the risk of fire this appliance MUST BE EXHAUSTED OUTDOORS Most installation will require at least 5 inch clearance behind the dryer for the dryer vent Location must be large enough to fully open dryer door SURE CONNECTTM Vent Kit CRUSH RESISTANT Dura SafeTM Kits Make Installat...

Страница 9: ...ance The Whirlpool Customer Interaction Center will answer any questions about operating or maintaining your washer dryer not covered in the Installation Instructions The Whirlpool Customer Interaction Center is open 24 hours a day 7 days a week Just dial 1 800 253 1301 the call is free When you call you will need the washer dryer model number and serial number Both numbers can be found on the mod...

Отзывы: