FIELD SERVICE
REPLACEMENT OF THE SSR (Solid State Relay) (PN 96225)
19
1 . Remove the lower bottom panel (Figure 2, Page 7) .
2 . Note and record the color and location of each of the four wires on the SSR terminals (Figure 5, Page 17) .
Remove each of the four wires by pulling straight up on the connecter . DO NOT PULL ON THE WIRES .
3 . Remove the two nuts and screws that hold SSR in place . Lift SSR off the chassis (Figure 5, Page 17) .
4 . Put the new SSR in place on the rear panel . Locate the SSR so that the center terminal will face downward
when the bottom panel is in place .
5 . Replace the four wires on the SSR (Figure 5, Page 17) .
6 . Replace the lower bottom panel (Figure 2, Page 7) .