___________________________________________________________________________
Infrastructure Installation Guide
___________________________________________________________________________ 23
Location Sensor Installation Guide
D0405 rev PA6
Copyright WhereNet, Corp. 2001
WhereNet Confidential
9
CABLING
Figure 11 below shows the connections which must be made to the Location
Sensor in normal operation. The connector types and recommended cable types
are detailed in section 4 above.
Left Right
Power
Antenna
Serial
Ethernet
Timing
Figure 11 Location Sensor connections
9.1
Power
The customer must provide 120 Vac power to the specified Location Sensor
position. The Location Sensor utilizes an external power supply to convert 120
Vac to the re18 to 36 Vdc. The recommended power supply has a 6 foot
(2 m) AC cable and a 6 foot (2 m) dc cable. The electrician should verify that the
AC power is available within 3 feet (1 m) of the position of the Location Sensor.