Whelen Engineering Company ISP9424A Скачать руководство пользователя страница 4

Page 4

Hi/Lo Mode

Type

Latched

Level

Toggle

DISABLED

Momentary

Momentary

NONE

Single Pole/

Single Throw

Apply +24VDC to

VIOLET control wire

Apply +24VDC to

VIOLET control wire

Apply +24VDC to

VIOLET control wire

No Lo Power Operation

In This Mode

Turn all strobe outlets

off and then on.

Apply +24VDC to

VIOLET control wire

Not

Applicable

24VDC from

VIOLET control wire

OFF

ON

OFF

ON

OFF

OFF

ON

ON

Recommended

Switch type

To Enable

Lo Power Operation

To Restore

Hi Power Operation

Dip Switch

3

Dip Switch

4

If the

LED is...

OFF

ON continuously

ON continuously

with a single flash

every few seconds

Flashing

rapidly

Either the outlet in question is not enabled, or the power supply is not turned on.

The outlet, strobe cable and strobe light in question are functioning properly.

Either the outlet, strobe cable and/or strobe light in question are malfunctioning.
In this condition, further investigation of the components is strongly recommended

The ISP is operating in Lo power mode.

then...

ISP9424A Wiring Diagram

Table 2

Table 1

Table 3

FLASH PATTERNS:

=

+12VDC

TRIPLE FLASH

MICRO-BURST 3

MICRO-BURST 2

SEQUENTIAL

MODU-FLASH

RAPID RANDOM

DOUBLE FLASH

COMET FLASH*

4

3

2

1

PATTERN

WIRE

PATTERN TYPE

* Only pattern available in

Serial Communication mode

Pattern Wire 1 = BROWN
Pattern Wire 2 = WHITE
Pattern Wire 3 = GREY
Pattern Wire 4 = ORANGE

ALL SWITCHES ARE CUSTOMER SUPPLIED

WHELEN

DIAGNOSTIC

INDICATOR

4

3

2

1

INDICATOR PANEL

TO DIAGNOSTIC

PATTERN 4

PATTERN 2

PATTERN 1

WHITE

BROWN

ORANGE

PATTERN 3

GREY

BLUE

CTRL 3

DIP SWITCH

CONFIGURATION

COMM.

CONTROL

PATTERNS

POWER

1-CTRL 1
2-CTRL 2
3-CTRL 3
4-LO PWR

3&4

1&2 + BAT.

GROUND

ALTERNATING

ALTERNATING

OUTLETS

1

2

3

4

RED

RED

BLACK
BLACK

VIOLET

YELLOW
GREEN

WHITE

RED
BLACK

TO DESIRED LIGHTHEAD
ASSEMBLY.
(TYP. 4 PLACES)

24V BATTERY

POS

GROUND

CTRL 1

CTRL 2

LO PWR

(SUPPLIED BY

3 AMP FUSE

CUSTOMER)

7.5 AMP FUSE
(SUPPLIED BY

CUSTOMER)

®

DIAGNOSTIC

1 2 3 4 5

V-INPUT
I-IN @12.8V
FLASHRATE

JOULES HI (per lamp)
JOULES LO
OUTPUT POWER
OUTPUT PER OUTLET

(per lamp)

ISP9424A SPECIFICATIONS

25.6

±

4

8

3.5

3.5

3.5

2

2

2

2

VDC 20%

.5 AMPS TYP.

ALT. 2X2
SIMUL. 2X2
SIMUL. 2X1X1
S.C.

/

/

/

(TYP)

/

/

/

(MIN)

90 WATTS (TYP)
22.5 WATTS (TYP)

150 FPM, COMET
140 FPM, COMET
140 FPM, COMET
150 FPM, COMET

25 ft. Communication Cable

(Twisted Pair)

P/N 46-9641638250

GREY

BLUE

FUSE

BLUE:

to RS485A

GREY:

to RS485B

TO

S.C.

Network