Whelen Engineering Company FastTrax FTF5 Скачать руководство пользователя страница 7

Page 7 of 9

A Note On Painting the FastTrax Housing...

If painting or re-painting 

your FastTrax™ housing, it 
is important to keep in mind 
the following information:

Do not apply paint or 
primer to any of the 
black-colored area 
immediately adjacent 
to the clear outer lens!

Do not apply paint or 
primer to the under-
side of the housing.

Make sure that all sur-
faces to be painted 
have been primed 
using primer that is 
suitable for ABS plas-
tic.

Be sure to include the 
leading edges (mate-
rial thickness) in your 
painting surfaces.

STROBE SPECIFICATIONS

INPUT VOLTAGE  - - - - - - - - - - - - - - 12.8 VDC ± 20%
INPUT CURRENT

2 STROBES - - - - - - - - - - - 4.5 AMPS (TYP)
4 STROBES - - - - - - - - - - - 9 AMPS (TYP)
6 STROBES - - - - - - - - - - - 13.5 AMPS (TYP)
8 STROBES - - - - - - - - - - - 18 AMPS (TYP)

INPUT POWER - - - - - - - - - - - - - - - - 230 WATTS (TYP)
ANODE VOLTAGE- - - - - - - - - - - - - - 450 VDC (MAX)
TRIG. VOLTAGE - - - - - - - - - - - - - - - 150 VDC (MIN)
ENERGY PER FLASH - - - - - - - - - - - 7.9 / 3.8 / 3.8 / 3.8
FLASHRATE - - - - - - - - - - - - - - - - - - 140 CFPM
OUTPUT POWER - - - - - - - - - - - - - - 22.5 WATTS (TYP)
(PER OUTLET)

HALOGEN SPECIFICATIONS

INPUT VOLTAGE  - - - - - - - - - - - - - - 12.8 VDC ± 20%
INPUT CURRENT

2 LAMPS - - - - - - - - - - - - - 4.5 AMPS (TYP)

INPUT POWER - - - - - - - - - - - - - - - - 230 WATTS (TYP)
OUTPUT VOLTAGE- - - - - - - - - - - - - INPUT VOLTAGE - 1V
ON TIME - - - - - - - - - - - - - - - - - - - - 125 mS (TYP)
OFF TIME- - - - - - - - - - - - - - - - - - - - 125 mS (TYP)
FLASHRATE - - - - - - - - - - - - - - - - - - 120 DFPM ±5%
OUTPUT POWER - - - - - - - - - - - - - - 50 WATTS (MAX)
(PER OUTLET)

DIAGNOSTIX

15A

-

HAL.

1-4

15A

-

HAL.

5-8

15A

-

STR.

1-4

15A

-

STR.

5-8

CONTROL

SERIAL

COMMUNICA

TIONS

DIAGNOSTICS

H1

H2

H3

H4

H6

H5

H7

H8

S1

S2

S3

S4

S6

S5

S7

S8

12V BATTERY

CUSTOMER SUPPLIED

45 AMP FUSE

BLK

RED

®

HALOGEN

TRAFFIC ADVISOR

STROBE

FTF5 DIP SWITCH

SETTINGS:

1

0FF

2

ON

3

ON

4

OFF

5

OFF

Содержание FastTrax FTF5

Страница 1: ... or currents Properly protect and use caution around live electrical connections Grounding or shorting of electrical connections can cause high current arcing which can cause personal injury and or vehicle damage including fire Many electronic devices used in emergency vehicles can create or be affected by electromagnetic interference Therefore after installation of any electronic device it is nec...

Страница 2: ...e between the fuse block and the positive battery terminal WARNING All customer supplied wires that connect to the positive terminal of the battery must be sized to supply at least 125 of the maximum operating current and fused at the bat tery to carry the load CAUTION As it will be necessary to drill holes into the mounting surface the installer MUST be sure that no vehicle components or other vi...

Страница 3: ... and H8 This will insure that the lightheads are connected to their proper power supply port A lighthead s identity is determined by what power supply port they are to be connected to Note Before the cables are routed the installer may wish to apply a light coating of sili cone spray to the cable s outer jacket This will allow the cables to be routed more easily The following section demonstrates ...

Страница 4: ...lar and down through the C pillar until it enters the trunk area of the vehicle In the trunk route the cable bundle towards the ISP8HS The basic cable path is as shown Repeat this entire procedure using a cable bundle consisting of the remaining cables S1 S3 S5 S7 and H4 bundled together and routed along the driver side support brace Insert the cable wire terminals into their plug connectors as fo...

Страница 5: ...e that will be in contact with the adhesive tape PLUS an additional inch and a half 1 wide area on either side of the tape will have to be prepared This area is called the bonding surface Remove the FastTrax housing from the vehicle 3 The bonding surface must be completely clean and dry Using a clean lint free cloth clean the bonding surface with an automotive wax and grease remover ex Prepsol All...

Страница 6: ...ion the control head on the proposed mounting location Using a pencil or other suitable tool scribe the mounting surface where the holes are to be drilled CAUTION As mounting the control head will require drilling it is absolutely necessary to make sure that no vehicle components could be damaged by the mounting process Check both sides of the mounting surface before starting and if damage is poss...

Страница 7: ... 2 STROBES 4 5 AMPS TYP 4 STROBES 9 AMPS TYP 6 STROBES 13 5 AMPS TYP 8 STROBES 18 AMPS TYP INPUT POWER 230 WATTS TYP ANODE VOLTAGE 450 VDC MAX TRIG VOLTAGE 150 VDC MIN ENERGY PER FLASH 7 9 3 8 3 8 3 8 FLASHRATE 140 CFPM OUTPUT POWER 22 5 WATTS TYP PER OUTLET HALOGEN SPECIFICATIONS INPUT VOLTAGE 12 8 VDC 20 INPUT CURRENT 2 LAMPS 4 5 AMPS TYP INPUT POWER 230 WATTS TYP OUTPUT VOLTAGE INPUT VOLTAGE 1V...

Страница 8: ...ton 2 Push Button 3 Flash Pattern OFF ON OFF ON OFF Comet Flash Default Double Flash Rapid Rate Action Flash OFF ON ON Not Used Push Button 4 Control Table Not Used Push Button 4 Control Table Push Button 6 Effect PUSH 1 Hi Power Mode Lo Power Mode PUSH 2 Push Button 6 Control Table Model FTF5 Push Button 1 Control Table Model FTF5 Only Push Button 1 Effect OFF None T D H5 H8 On ON Model FTF5 1 5 ...

Страница 9: ... 5 8 PFHSMS 100Ê BLACK ZINC OXIDE 15 08121B 106 6 1 1 LABEL REGISTERED TRADE MARK 10 0322504 02 5 1 1 LENS NON OPTIC CLEAR 68 3183242 31 4 A R 1 A R 3 38 0522686 00 GASKET D SHAPE W PSA 01 0683334 01 ASS Y 8 STROBE 0 HAL PAINTED 2 11 483241 001 HOUSING PAINTED 1 1 11 483241 000 HOUSING AS MOLDED DESCRIPTION ASS Y 8 STROBE 0 HAL RAW PART NUMBER 01 0683334 00 ITEM QTY 20 02 0342292 01 ASS Y REFLECTO...