background image

Page 7

STROBE SPECIFICATIONS

INPUT VOLTAGE - - - - - - - 12.8 VDC 

±

 20%

INPUT CURRENT

2 STROBES  - - - - - 4.5 AMPS (TYP)
4 STROBES  - - - - - 9 AMPS (TYP)

INPUT POWER  - - - - - - - - 115 WATTS (TYP)

ANODE VOLTAGE - - - - - - 450 VDC (MAX)

TRIG. VOLTAGE  - - - - - - - 150 VDC (MIN)

ENERGY PER FLASH  - - - 7.9 / 3.8 / 3.8 / 3.8

FLASHRATE  - - - - - - - - - - 140 CFPM

OUTPUT POWER  - - - - - - 22.5 WATTS (TYP)

(PER OUTLET)

HALOGEN SPECIFICATIONS

INPUT VOLTAGE  - - - - - -  12.8 VDC 

±

 20%

INPUT CURRENT

2 LAMPS - - - - - - -  4.5 AMPS (TYP)
4 LAMPS - - - - - - -  9 AMPS (TYP)

INPUT POWER - - - - - - - -  115 WATTS (TYP)

OUTPUT VOLTAGE- - - - -  INPUT VOLTAGE - 1V

ON TIME  - - - - - - - - - - - -  125 mS (TYP)

OFF TIME- - - - - - - - - - - -  125 mS (TYP)

FLASHRATE - - - - - - - - - -  120 DFPM 

±5%

OUTPUT POWER - - - - - -  50 WATTS (MAX)

(PER OUTLET)

ALTERNATING

OUTLET S1

OUTLET H1

WHITE/RED

5

H2 & H4 Alleys On (flashing)

GREY

9

YELLOW

H1 & H3 On

8

GREEN

S2 & S4 On

7

BLUE

S1 & S3 On

6

VIOLET

10

RED

1

BLACK

3

BATTERY

15 AMP FUSE

CUSTOMER SUPPLIED

DS 1 - OFF
DS 2 - OFF
DS 3 - ON

1

2
3
4

DS 4 - ON

WIRING DIAGRAM

2

WHITE

15 AMP FUSE

4

BLACK

OUTLET H2

OUTLET S2

SIMULTANEOUS

SIMULTANEOUS

OUTLET S3

OUTLET H3

OUTLET S4

OUTLET H4

HALOGEN OUTLET

STROBE OUTLET

HALOGEN OUTLET

STROBE OUTLET

STROBE OUTLET

HALOGEN OUTLET

HALOGEN OUTLET

STROBE OUTLET

H2 & H4 Alleys On (steady)

Содержание FastTrax FTF2

Страница 1: ... currents Properly protect and use caution around live electrical connections Grounding or shorting of electrical connections can cause high current arcing which can cause personal injury and or vehicle damage including fire Many electronic devices used in emergency vehicles can create or be affected by electromagnetic interference Therefore after installation of any electronic device it is necess...

Страница 2: ...n the fuse block and the positive battery terminal WARNING All customer supplied wires that connect to the positive terminal of the battery must be sized to supply at least 125 of the maximum operating current and fused at the battery to carry the load CAUTION As it will be necessary to drill holes into the mounting surface the installer MUST be sure that no vehicle components or other vital parts...

Страница 3: ...ly port A lighthead s identity is determined by what power supply port they are to be connected to An additional two halogen cables must be used to connect the Take Down T D lamps to a switched 12VDC power source Use a marker to identify these cables T D1 T D2 Note Before the cables are routed the installer may wish to apply a light coating of silicone spray to the cable s outer jacket This allows...

Страница 4: ...d down through the C pillar until it enters the trunk area of the vehicle In the trunk route the cable bundle towards the ISP8HS The basic cable path is as shown Repeat this entire procedure using a cable bundle consisting of the remaining cables S1 S4 H1 H4 and TD 2 bundled together and routed along the driver side support brace Insert the cable wire terminals into their plug connectors as follow...

Страница 5: ...alf 1 wide area on either side of the tape will have to be prepared This area is called the bonding surface Remove the Fast Trax housing from the vehicle 3 The bonding surface must be completely clean and dry Using a clean lint free cloth clean the bonding surface with an automotive wax and grease remover ex Prepsol Allow to dry thoroughly 4 Shake the 3M Keel Primer applicator included well before...

Страница 6: ...in mind the following information Do not apply paint or primer to any of the black colored area immediately adjacent to the clear outer lens Do not apply paint or primer to the underside of the housing Make sure that all surfaces to be painted have been primed using primer that is suitable for ABS plastic Be sure to include the leading edges material thickness in your painting surfaces FTF2 4 Stro...

Страница 7: ...OLTAGE INPUT VOLTAGE 1V ON TIME 125 mS TYP OFF TIME 125 mS TYP FLASHRATE 120 DFPM 5 OUTPUT POWER 50 WATTS MAX PER OUTLET ALTERNATING OUTLET S1 OUTLET H1 WHITE RED 5 H2 H4 Alleys On flashing GREY 9 YELLOW H1 H3 On 8 GREEN S2 S4 On 7 BLUE S1 S3 On 6 VIOLET 10 RED 1 BLACK 3 BATTERY 15 AMP FUSE CUSTOMER SUPPLIED DS 1 OFF DS 2 OFF DS 3 ON 1 2 3 4 DS 4 ON WIRING DIAGRAM 2 WHITE 15 AMP FUSE 4 BLACK OUTLE...

Страница 8: ...ROBE 4 HAL PAINTED 2 11 483241 001 HOUSING PAINTED 1 1 11 483241 000 HOUSING AS MOLDED DESCRIPTION ASS Y 4 STROBE 4 HAL RAW PART NUMBER 01 0683334 02 ITEM QTY 20 02 0342292 01 ASS Y REFLECTOR DUAL HALOGEN 12V 27H 1 1 21 13 062C40 16J 6 SCREW GROMMET 242 160502 70 10 10 A R A R TAPE VHB DOUBLE STICK BLACK 66 0416678 00 22 23 10 Not Shown Not Shown Not Shown 2 28 1 LABEL CABLE I D 10 0742600 02 1 29...

Отзывы: