Specifications:

Input Voltage

 . . . . . . . . . . . . . . . . . . 10 - 30 VDC Negative Ground Only

Main Input Current

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  Amps

 

Stand-by Current (no ignition)

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

80mA

Operating Temperature

. . . . . . . . . . . . . . . . . . . . . . . . . . -40°C to +65°C

Storage Temperature

 . . . . . . . . . . . . . . . . . . . . . . . . . . . -40°C to +70°C

Humidity

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99% (Non-condensing)

3 Digital Inputs / 4 Analog Inputs / 1 Ignition Sense
Dimensions

Height

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.46 inches

Width

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.76 inches

Depth

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.11 inches

Installation:

1. Locate a suitable mounting location. A dry, cool compartment is a good

choice. 

2. Position the Core-R module on the proposed mounting location. Using

an awl or similar tool, scribe the mounting surface where the mounting

holes  are  to  be  drilled.  Make  sure  that  this  mounting  area  allows

sufficient ventilation for the Amplifier module’s air vents.

Caution:Mounting will require drilling, it is absolutely necessary to

make sure that no other vehicle components could be damaged in

the  process.  Check  both  sides  of  the  mounting  surface  before

starting. If damage is likely, select a different mounting location.

3. Remove the module from its mounting area, and using a drill bit sized

for a #8 sheet metal screw, drill a hole in each of the areas scribed in

the previous step.

4. Return  the  module  to  its  mounting

location  and  using  #8  x  3/4”  sheet

metal 

screws 

(provided),

secure  the  module  onto  its

mounting  surface.  Be

sure  to  install  a  #8

internal  tooth  lock

washer  (included)  onto

each  mounting  screw  before

mounting the unit.

Wiring:

WARNING! All customer supplied wires that connect to the positive

terminal of the battery must be sized to supply at least 125% of the

maximum operating current and FUSED at the battery to carry that

load. DO NOT USE CIRCUIT BREAKERS WITH THIS PRODUCT!
Wires  connecting  to  the  Amp/Relay  Module  have  the  proper

terminals pre-installed. If the customer needs to re-terminate these

wires for any reason, the proper tool MUST be used to ensure proper

crimping.  Use  the  AMP  Pro  Crimper  II  (P/N#  354940-1)  with  die

#90572-2 for items 6-26 and die #58495-2 for items 30-50. WHELEN

DOES  NOT  RECOMMEND  RETERMINATING  ANY  OF  THE

ANDERSON™ CONNECTORS.

Amp/Relay Module Fuses

For ease of access, all of the amp/relay module fuses are accessible from

outside the case.

Main Power (J3):

1. Route  the  RED  wire  to  the  positive  battery  terminal  and  fuse  at 

10

AMPS

2. Route the BLACK wire to the vehicle’s chassis ground typically adjacent

to the battery.

Programmable Inputs:

There are 3 digital and 4 Analog programmable inputs in the Core-R 

system.

Digital Inputs (J3) (Pins 2, 3, 4)

These digital inputs can be configured to detect either a positive or ground

signal.

Analog Inputs and Ignition Sense (J3)

Analog Inputs (Pins 5, 8, 9, 10)

These  inputs  can  detect  a  varying,  analog  voltage  range.  The  output

signal  line  from  devices  such  as  a  K-9  temperature  sensor  may  be

connected to these inputs.

Ignition Sense (Pin 7)

This  input  should  be  wired  to  an  ignition  signal  and  controls  when  the

Core-R system turns on (when ignition is detected) and when the system

turns off (when ignition line turns off). The Core-R system turning off can

be further configured by programing a Shutdown Delay to keep the system

active after the ignition signal turns off.

Dry Contact Relay (J4)

 (See “Hands Free Siren”)

• 15 Amp Max, Fused
• Pin 1 is the Normally Open terminal.
• Pin 2 is the relay’s Common terminal.
• Pin 3 is the Normally Closed terminal.

650 A

m

Bosch™ Style

(Tyco-P&B P/N:VF4-45F11)

(customer supplied)

Dry Contact Relay

Switched as output 23

(recommended)

T

o

 V

eh

i

c

l

e

 C

ar

 

Horn

F

rom

 V

eh

i

c

l

e

Horn

 

Re

l

a

y

T

oA

n

Output

T

o

 

an

y I

nput

 

conf

i

gured

as

 

Horn

 

R

i

ng

30

87A

85

86

87

Generic Style Relay

(customer supplied)

T

oA
n

Output

T

oa

n

yI

nput

conf

i

gured

 

as

Horn

 

R

i

ng

T

o

 V

eh

i

c

l

e

C

ar

 

Horn

NO

N

C

F

rom

 V

eh

i

c

l

e

 

Horn

 

Re

l

a

y

J4

D

RY

C

ON

T

A

CT

R

E

LAY

HORN

 

R

I

N

G

C

ut

 

connect

i

on

b

et

w

een

 

horn

 

r

i

ng

and

 

factor

horn

3 - 

OR

G

2 - 

R

ED

1

 - B

RN

Norma

lly Cl

osed

 - T

o

V

eh

i

c

l

e

 C

ar

 

Horn

C

O

MM

ON

 - F

rom

V

eh

i

c

l

e

 

Horn

 

Re

l

a

y

Norma

lly 

Open

Horn

 

R

i

ng

 I

nput

I

f

 

the

 

horn

connect

i

on

 i

s

pos

i

t

i

ve

 

1

2V, 

the

l

oad

 

shou

l

d

 

not

e

x

ceed

 

10 A

MP

S.

T

o

 T

ransfer

 

Horn

 

for

 

H

F, 

act

i

vate

J4 - 

1

, 2, 3 

dr

contact

 

con

fi

gurat

i

on

VE

H

IC

L

E

HORN

T

o

 I

nput

 

1

W

H

T/B

RN

Отзывы: