P R O G R A M M I N G G U I D E
10
CenCom Sapphire™
Micro-Link configuration Default Settings
SWITCH LEGEND
FUNCTION
OUTLETS
1 Siren arm and font blues
including L-bar
Grille/fend, lightbar blues and siren arm
2
9
WeCan® Default hidden
(IDR O/P)
2 Rear blues
All lightbar rear blues and tailgate blues
WeCan® 4 &N4
3 Headlight flash
Vehicle headlight flash (separate flasher)
WeCan® 3
4 Rear Reds
Lightbar rear reds and tailgate reds
WeCan® 5 & N5
5 Left Alley
Left alley light
10
6 Right alley
Right alley light
WeCan® 11
INPUTS
SWITCH/
FUNCTION
OPERATIONS
POLARITY
OF INPUT
OUTPUT
R1
Handbrake
STRVU
Turns run lock off and turns siren
test volume reduction if wired in
Negative
8 On (if run lock active,
this turns off 6&7)
R2
Tailgate switch
Turning on and off of tailgate
blues/reds
Live
Press on
release off
N4 &N5
R3
Delayed outputs
for sockets or
radios etc.
Using the CenCom™ shutdown
delay timer keeps these circuits
alive once the ignition has been
turned off for the delay period set
Negative
Press on
release off
1 On
R4
Horn Ring
Siren tone activation and tone
change
Live
Press on
release off
R5
Foot brake
Turns run lock off
Live
Press on
release off
(If run lock active, this
turns off 6 & 7)
R6
Run lock
Activates run lock on outputs 6 & 7
Live
4 hours
6 & 7 default hidden
R7
Remote 999
Remote 999
Live
R8
Input 8
No preset
Negative
R9
Input 9
No preset
Negative
R10
Air horn
Negative
Additional Input Operations