T3  (Piercer

TM

  Tone)

  -  When  the  rotary  knob  is  in  the  T3

position, an extremely fast, rise and fall tone is produced. May
be used for HI / LO and mechanical wail in some applications.

With the Rotary Switch in this Position:

Pressing the MAN switch will result in the AIRHORN tone until 
the MAN switch is released.

Pressing the horn switch will result in the AIRHORN tone until 
the HORN switch is released.

Activating the HORN RING input will result in the AIRHORN 
tone until the man switch is released.

Activating the SIREN SHUTDOWN input will shut the 
PIERCER tone down. However the HORN and the HORN RING 
switch will activate an AIRHORN tone, and the MAN switch 
will activate a momentary WAIL tone.
NOTE: Model 295HFSM1 will initiate ‘Siren Brake’.

Activating the AUX ENABLE will have no effect.

NOTE:

 

Models 295HFSA1 / 295HFSE1 and 295HFSC1 / 295HFSH1 
produce the PIERCER tone when T3 is selected.

Models 295HFSB1 / 295HFSF1 and 295HFSD1 / 295HFSJ1 
produce the HI / LO tone when T3 is selected.

Model 295HFSM1 produces mechanical wail when T3 is 
selected.

Model 295HFSW1 produces a WHOOP tone when T3 is 
selected (with WARBLE as the override tone).

Microphone:

Whenever  the  unit  is  powered  on,  activating  the  microphone
(pressing the switch on the side of the mic.) will shut down any
other  siren  functions  &  enable  public  address  operation
regardless  of the rotary  switch  position  or  any  other  switch  or
input.

SPECIFICATIONS

INPUT VOLTAGE

 . . . . . . . . . . . . . . . . . . . . . .  12.5 VDC ±20% 

INPUT CURRENT 

@15 VDC @ 5.5 OHMS  . . . 16 AMPS MAX.

INPUT FUSE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 AMPS

SPEAKER IMPEDANCE

. . . . . . . . . . . . . . . . .  5.5 OHMS MIN.

OPERATING TEMPERATURE

 . . . . . . . . . . -30° C. TO +60° C.

STORAGE TEMPERATURE

. . . . . . . . . . . . -40° C. TO +70° C.

HUMIDITY

 . . . . . . . . . . . . . . . . . . .  99% (NON CONDENSING)

SPECIFICATIONS / 24 Volt Models

INPUT VOLTAGE

 . . . . . . . . . . . . . . . . . . . . . .  25.5 VDC ±20%

INPUT CURRENT 

@28 VDC @ 5.5 OHMS  . . . . 8 AMPS MAX.

INPUT FUSE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 AMPS

SPEAKER IMPEDANCE

. . . . . . . . . . . . . . . . .  5.5 OHMS MIN.

OPERATING TEMPERATURE

 . . . . . . . . . . -30° C. TO +60° C.

STORAGE TEMPERATURE

. . . . . . . . . . . . -40° C. TO +70° C.

HUMIDITY

 . . . . . . . . . . . . . . . . . . .  99% (NON CONDENSING)

Diagnostic Indicators:

This unit has two diagnostic indicators on the front panel which
are used to indicate fault conditions with your siren system. The
following table lists the type of fault and the indicators response.
If the indicator is on steady while a tone is in use, this implies
that there is no fault with the associated speaker output. 

Fault Condition

Diagnostic Indicators Response

Under Voltage

Speaker L.E.D. #2 will be in a double 
flash mode (2 quick flashes followed 
by a longer pause) and the siren 
tones will not operate.

Over Voltage

Speaker L.E.D. #1 will be in a double 
flash mode (2 quick flashes followed 
by a longer pause) and the siren 
tones will not operate

.

Speaker #1
Short Circuit

Speaker L.E.D. # 1 will be in a single 

flash mode (the L.E.D. will be on and 
off an equal

 

amount of time) and the 

siren tones will not operate.

Speaker #2
Short Circuit

Speaker L.E.D. #2 will be in a single 

flash mode (the L.E.D. will be on and 
off an equal

 

amount of time) and the 

siren tones will not operate.

Speaker #1
Open Circuit

Speaker L.E.D. #1 will be off (having a 

single speaker system will always 
cause this condition for the speaker 
output not in use) all tones will 
continue to operate.

Speaker #2
Open Circuit

Speaker L.E.D. #2 will be off (having 
a single speaker system will always 
cause this

 

condition for the speaker 

output not in use) all tones will 
continue to operate.

CAUTION

Loud siren noise can cause
hearing damage and/or loss.

Refer to OSHA Section 1910.95 prior
to putting ANY siren into service!

Wear

Protection!

ACTIVATION OF THIS