Wheelock TPI-100 Скачать руководство пользователя страница 2

P82030 K 

Sheet 2 of 17 

  

GENERAL APPLICATION INFORMATION: 

 
The Telephone Paging Interface (TPI-100) provides ring start (90V/20Hz) paging access from: 

 

A.  A Central Office (CO) line. 
B.  A Centrex number line. 
C.  A station level position on telephone systems which provide analog ring voltage (90V/20Hz), and 600 OHM audio to their 

extension phones. 

 

The TPI-100 is a ring detector that monitors the line for ring voltage.  When ring voltage is detected, the caller is connected to 
the paging system. 

 

Paging is accomplished by touch tone (DTMF) dialing the CO line, Centrex line, or station extension number.  After one ring, 
the TPI-100 will simultaneously: 

 

A.  Generate a single Confirmation Tone to the caller. 
B.  Generate a single Page Alert Tone to the paging system. 
C.  Connect the caller to the paging system. 

 

The Confirmation/Page Alert Tone volume is internally adjustable, and has an "Off" position. 

 

When a caller hangs up the telephone at the conclusion of a page, some telephone systems generate an immediate Hang Up Tone 
to the paging system, some generate a delayed Hang Up Tone, while others remain silent.  The TPI-100 can interface a paging 
system with all of these telephone systems, because it will disconnect the paging system before the Hang Up Tone can be 
transmitted over the paging system speakers. 

 

For telephone systems that generate a delayed or immediate Hang Up Tone, the TPI-100 is equipped with a variable Frequency 
Detector (200 to 950Hz) which is adjusted during installation to detect the telephone system's specific Hang Up Tone frequency.  
When that frequency is detected on Tip and Ring, the TPI-100 will disconnect the paging system. 

 

For telephone systems that generate a Hang Up Tone with a frequency that cannot be detected by  the TPI-100's Frequency 
Detector, or for telephone systems that do not generate a Hang Up Tone (remain silent), the TPI-100 is equipped with a variable 
Page Duration Timer (3 to 51 seconds).  The timer is set during installation to disconnect the paging system by: 

 

A.  Timing out before the occurrence of the Hang Up Tone or… 
B.  Simply timing out, for telephone systems that remain silent. 

 

Whenever the Tone Frequency Detector is used: 

 

A.  It will take precedence over the Page Duration Timer. 
B.  The Page Duration Timer is placed in the maximum (51 seconds) position. 

 

Chart 1 shows the proper application of the Tone Frequency Detector and the Page Duration Timer. 
 

 

Telephone System 

"Hang Up" Tone 

Tone Frequency 

Detector 

Page Duration 

Timer 

Immediate Yes 

Yes 

Delayed Yes 

Yes 

Cannot be detected by
Frequency Detector 

 

No 

 

Yes 

None (Silent) 

No 

Yes 

 

 

Chart 1. 

Application of Tone Frequency Detector and Page Duration Timer 

 
The Page Duration Timer is programmed for "VOX" (Voice Operated) or "MAN." (Manual) control using the Timer Control 
Jumper, as shown in Chart 2. 
 
 

 

Position of Timer Control Jumper for: 

Position of 

Содержание TPI-100

Страница 1: ...blem has been corrected Should the equipment cause harm to the telephone network the telephone company shall if possible notify the customer that temporary discontinuance of service may be required ho...

Страница 2: ...ems that generate a delayed or immediate Hang Up Tone the TPI 100 is equipped with a variable Frequency Detector 200 to 950Hz which is adjusted during installation to detect the telephone system s spe...

Страница 3: ...he TPI 100 will disconnect the paging system when the preset time has elapsed NOTE Voice signals of the same frequency as the Hang Up Tone may cause the TPI 100 to disconnect If the TPI 100 disconnect...

Страница 4: ...ne system consisting of a single TPI 100 and a single TBM 101 talkback speaker system or TBH 104 talkback horn system One TBM 101 or TBH 104 may be used with a TPI 100 Depending upon the telephone sys...

Страница 5: ...ed speakers horns The Timer Control Jumper should be placed in the VOX position Figure 4 Single Line Multi Zone Paging Figure 4 depicts a multi zone system consisting of a single TPI 100 and an FZC 3...

Страница 6: ...n tone TO ACCESS ALL ZONES SIMULTANEOUSLY dial the number of the line connected to the TPI 100 controlling All Call If individual zone paging is in progress when an All Call page is initiated then an...

Страница 7: ...igned to each page group and to All Call The paging devices connected to the TPI 100 s can be any of the configurations shown in Figures 1 thru 4 The TPI 100 s controlling the individual zones should...

Страница 8: ...phone as a confirmation tone If individual zone paging or group paging is in progress when an All Call page is initiated then an alert tone will be signaled back to the zone and or group paging telep...

Страница 9: ...dance 600 OHMS Hang Up Tone Detect Frequency Range 200hz to 950Hz Hang Up Tone Detect Time 250m Seconds Page Duration Timer Range 3 to 51 Seconds Operating Temperature Range 0 to 55 Degrees C Operatin...

Страница 10: ...ll individual zone TPI 100 s B Connect TB1 terminal 6 from the All Call TPI 100 to TB1 terminal 4 of all individual zone TPI 100 s 7 In multiple line applications with Group Page and All Call A Connec...

Страница 11: ...P82030 K Sheet 11 of 17 Figure 9 Installation Programming and Tone Volume Adjustment Diagram...

Страница 12: ...Talk Battery TPI 100 selector switch to the TPI 100 position 2 If TPI 100 and FZC 3 use separate power supplies then install wire between GND TB1 terminal 5 on TPI 100 and GND TB1 terminal 4 on FZC 3...

Страница 13: ...MAN pins for preset time out of the Page Duration Timer The Tone Detect Jumper is shown in Figure 12 Figure 12 Tone Detect Jumper When shipped from the factory the two position jumper is placed over t...

Страница 14: ...shown in Figure 14 It is used with telephone systems with a delayed Hang Up Tone that cannot be detected by the frequency detector or with systems that do not generate a Hang Up Tone remain silent For...

Страница 15: ...y times how long it takes for the telephone system to generate its Hang Up Dial or Reorder tone D Set the Page Duration Timer for just under the amount of time it takes the telephone system to generat...

Страница 16: ...nput ACI All Call Output ACO and Zone Control Output ZCO wiring 4 Verify unit has released from last page 2 No sound or low page volume 1 Check presence and level of audio input at Tip and Ring termin...

Страница 17: ...WARE WILL MEET THE USER S REQUIREMENTS WHEELOCK SHALL NOT BE LIABLE FOR ANY DELAYS BREAKDOWNS INTERRUPTIONS LOSS DESTRUCTION ALTERATION OR OTHER PROBLEMS IN THE USE OF A PRODUCT ARISING OUT OF OR CAUS...

Отзывы: