P84030 D 

Sheet 5 of 10

 

LIGHT DISTRIBUTION PER UL 1971: 

 

Table 4: Horizontal Plane 

Horizontal 15cd 

30cd 

75cd 

110cd 

Angle (in deg.) 

UL Min. 

Typ. 15cd 

UL Min. 

Typ. 30cd 

UL Min. 

Typ. 75cd 

UL Min. 

Typ. 110cd 

  0 

15.0 

24 

30.0 

46 

75.0 

103 

110.0 

149 

  5 

13.5 

24 

27.0 

46 

67.5 

103 

  99.0 

152 

10  13.5 24 27.0 45 67.5 104  

 

99.0 151 

15  13.5 24 27.0 46 67.5 100  

 

99.0 151 

20  13.5 23 27.0 43 67.5 101  

 

99.0 148 

25  13.5 23 27.0 43 67.5 98  

 

99.0 140 

30  11.3 21 22.5 41 56.3 94  

 

82.5 135 

35  11.3 20 22.5 40 56.3 89  

 

82.5 129 

40  11.3 14 22.5 39 56.3 83  

 

82.5 124 

45  11.3 18 22.5 41 56.3 81  

 

82.5 133 

50 

  8.3 

18 

16.5 

36 

41.3 

77 

  60.5 

121 

55 

  6.8 

12 

13.5 

27 

33.8 

60 

  49.5 

85 

60 

  6.0 

11 

12.0 

30 

30.0 

59 

  44.0 

95 

65 

  5.3 

13 

10.5 

35 

26.3 

71 

  38.5 

113 

70 

  5.3 

17 

10.5 

29 

26.3 

73 

  38.5 

81 

75 

  4.5 

13 

  9.0 

22 

22.5 

53 

  33.0 

72 

80 

  4.5 

  9.0 

17 

22.5 

35 

  33.0 

50 

85 

  3.8 

  7.5 

15 

18.8 

30 

  27.5 

38 

90 

 3.8 

  7.5 

15 

18.8 

30 

  27.5 

43 

 
 

Table 4A: Vertical Plane 

Vertical 15cd 

30cd 

75cd 

110cd 

Angle (in deg.) 

UL Min. 

Typ. 15cd 

UL Min. 

Typ. 30cd 

UL Min. 

Typ. 75cd 

UL Min. 

Typ. 110cd 

  0 

15.0 

24 

30.0 

46 

75.0 

103 

110.0 

149 

  5 

13.5 

24 

27.0 

46 

67.5 

103 

  99.0 

149 

10 

13.5 

24 

27.0 

46 

67.5 

103 

  99.0 

137 

15 

13.5 

24 

27.0 

45 

67.5 

102 

  99.0 

120 

20 

13.5 

24 

27.0 

41 

67.5 

104 

  99.0 

110 

25 

13.5 

21 

27.0 

48 

67.5 

89 

  99.0 

129 

30 

13.5 

23 

27.0 

40 

67.5 

96 

  99.0 

114 

35 

  9.8 

22 

19.5 

45 

48.8 

91 

  71.5 

119 

40 

  6.9 

13 

13.8 

39 

34.3 

57 

  50.6 

109 

45 

  5.1 

10.2 

24 

25.5 

36 

  37.4 

66 

50 

  4.0 

  8.1 

16 

20.0 

33 

  29.7 

45 

55 

  3.3 

  6.6 

15 

16.3 

31 

  24.2 

43 

60 

  2.7 

  5.4 

15 

13.5 

31 

  19.8 

40 

65 

  2.4 

  4.8 

14 

12.0 

31 

  17.6 

40 

70 

  2.3 

  4.5 

15 

11.3 

31 

  16.5 

39 

75 

  2.0 

  4.0 

14 

10.0 

31 

  14.3 

39 

80 

  1.8 

  3.6 

13 

  9.0 

27 

  13.2 

36 

85 

  1.8 

  3.6 

13 

  9.0 

27 

  13.2 

37 

90 

  1.8 

  3.6 

  9.0 

12 

  13.2 

28 

 

WARNING: WHEN INSTALLING STROBES IN AN OPEN OFFICE OR OTHER AREAS CONTAINING 

PARTITIONS OR OTHER VIEWING OBSTRUCTIONS, SPECIAL ATTENTION SHOULD BE GIVEN TO THE 
LOCATION OF THE STROBES SO THAT THEIR OPERATING EFFECT CAN BE SEEN BY ALL INTENDED 
VIEWERS, WITH THE INTENSITY, NUMBER, AND TYPE OF STROBES BEING SUFFICIENT TO MAKE SURE 
THAT THE INTENDED VIEWER IS ALERTED BY PROPER ILLUMINATION, REGARDLESS OF THE VIEWER'S 
ORIENTATION.  FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR 
DEATH TO YOU AND/OR OTHERS.

 

 

Содержание NS-1215W

Страница 1: ... lens to provide maximum visibility and reliability for effective visible signaling Series NS Appliances can be field set for High HI or Low LO dBA sound output These strobe models are designed for use with either filtered DC VDC or unfiltered Full Wave Rectified FWR input voltage All inputs are polarized for compatibility with standard reverse polarity supervision of circuit wiring by a FACP NOTE...

Страница 2: ...8 83 86 87 89 91 Low 67 72 74 82 84 86 Code 3 Horn High 75 79 82 87 89 91 WARNING OPERATING THE 24 VOLT NS AUDIBLE APPLIANCES SET ON CODE 3 HORN WITH LOW dBA AT MINIMUM VOLTAGE DOES NOT MEET THE 75dBA MINIMUM UL REVERBERANT SOUND LEVEL REQUIRED FOR PUBLIC MODE FIRE PROTECTION SERVICE NOTED BY IN TABLE 2 OPERATING THE 12 VOLT NS AUDIBLE APPLIANCES SET ON CODE 3 HORN WITH LOW dBA OR CONTINOUS HORN W...

Страница 3: ...10W 16 0VDC 0 181 0 265 0 482 0 675 24 0VDC 0 183 0 270 0 485 0 680 33 0VDC 0 188 0 275 0 489 0 685 16 0VRMS 0 183 0 270 0 485 0 680 24 0VRMS 0 188 0 275 0 489 0 685 33 0VRMS 0 430 0 480 0 520 0 690 Voltage NS 1215W 8 0VDC 0 460 12 0VDC 0 465 17 5VDC 0 470 8 0VRMS 0 465 12 0VRMS 0 470 17 5VRMS 0 475 Rated Inrush Current Voltage NS 2415W NS 2430W NS 2475W NS 24110W 16 0VDC 0 110 0 110 0 110 0 110 2...

Страница 4: ...LERT OCCUPANTS DURING AN EMERGENCY WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND OR OTHERS When calculating the total average peak or inrush currents Use Table 3 and 3A to determine the highest value of Rated Average Current for an individual strobe across the expected operating voltage range of the strobe and use Table 3 to determine the highest value of Rated Inrus...

Страница 5: ...n Typ 110cd 0 15 0 24 30 0 46 75 0 103 110 0 149 5 13 5 24 27 0 46 67 5 103 99 0 149 10 13 5 24 27 0 46 67 5 103 99 0 137 15 13 5 24 27 0 45 67 5 102 99 0 120 20 13 5 24 27 0 41 67 5 104 99 0 110 25 13 5 21 27 0 48 67 5 89 99 0 129 30 13 5 23 27 0 40 67 5 96 99 0 114 35 9 8 22 19 5 45 48 8 91 71 5 119 40 6 9 13 13 8 39 34 3 57 50 6 109 45 5 1 9 10 2 24 25 5 36 37 4 66 50 4 0 9 8 1 16 20 0 33 29 7 ...

Страница 6: ...ug JUMPER PLUGS TOP PLUG NO PLUG HI LOW CODE 3 HORN Factory setting is on High dB and Code 3 Figure 2 Jumper plug settings for High dB and Code 3 Figure 3 Jumper plug settings for Low dB and Continuous Horn SHOWN SET ON HI dB CENTER PIN IS NOT USED SHOWN SET ON CODE 3 CENTER PIN IS NOT USED SHOWN SET ON CONT HORN SHOWN SET ON LOW dB Figure 4 Jumper plug settings for Low dB and Code 3 Figure 5 Jump...

Страница 7: ... backbox to accommodate the field wires and stresses from the wires could damage the product Although the limits shown for each mounting option comply with the National Electrical Code NEC Wheelock recommends use of the largest backbox option shown and the use of approved stranded field wires whenever possible to provide additional wiring room for easy installation and minimum stress on the produc...

Страница 8: ...S Beauty Plate Second gently pull away from the wall with the inserted screwdriver to disengage the snap Third repeat the first and second steps for the second slot Finally gently lift the Beauty Plate away from the NSMP 6 Mounting hardware for each mounting option is supplied 7 Conduit entrances to the backbox should be selected to provide sufficient wiring clearance for the installed product 8 W...

Страница 9: ...system communication circuits and or audio circuits for example may require special precautions to assure immunity from electrical noise e g audio crosstalk NOTE This equipment has been tested and found to comply with the limits for a Class B digital appliance pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential...

Страница 10: ... SPECIFICATION ABUSE ACCIDENT OR OTHER OPERATING CONDITIONS BEYOND WHEELOCK S CONTROL SOME WHEELOCK PRODUCTS CONTAIN SOFTWARE WITH RESPECT TO THOSE PRODUCTS WHEELOCK DOES NOT WARRANTY THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR FREE OR THAT THE SOFTWARE WILL MEET ANY OTHER STANDARD OF PERFORMANCE OR THAT THE FUNCTIONS OR PERFORMANCE OF THE SOFTWARE WILL MEET THE USER S REQUIR...

Отзывы: