3-11
Section 3 • Systems & Components Overview & Operation
270 Outrage
R
• Activate the raw water pump by pressing the
RAW WATER switch on the console switch
panel.
• Fill the livewell by pressing the switch
marked “LIVEWELL PUMP” on the console
switch panel (See figure 2.13.1).
The livewell has three drains to regulate the amount of
water in the unit. The bottom drain is used to empty the
livewell of water completely.
By utilizing the drain plug
between the two overflow
drains in the side of the livewell
you can adjust the level of water
in the unit. A drain tube with
strainer connects to the livewell
overflow drains and will direct
overflow/excess water to the
transom thru-hull drain.
Raw Water Washdown
The raw water washdown hose connection is located
on the port aft of the cockpit (See figure 3.10.1). The
fitting allows for connection of a common garden
hose. It is important that the cap which is tethered to
the connection be screwed onto the fitting when it is not
being used. The raw water washdown is supplied by a
3.5 GPM (13.25L) pump activated by the “RAW
WATER” switch on the console switch panel (See figure
2.13.1).
Maintenance
Maintenance of the raw water system requires
periodic inspection of the raw water intake strainer
and all fittings and hoses for system integrity to
prevent leaks. Clean away debris and/or tighten hose
connections as required. The system should be run
at least every other month to keep the pumps
impellers in good condition. The Livewell and raw-water
washdown fitting is fed by the same pump. Access to
the pumpand seacock is through the lower aft interior of
the console.
If equipped, the Deluxe Leaning Post option has an
integrated 34 Gal. (129 L) livewell located aft of the
console seating area. The livewell is filled by a 12v/800
GPH pump and seacock which can be accessed through
the lower aft interior of the console.
A flow adjustment valve located at the forward starboard
base of the leaning post (behind an access door) allows
the operator to control the rate of water flow into the
livewell.
Bothe the seacock and valve must be open to fill the
livewell
Deluxe Leaning Post Livewell (Option)
NOTICE
The seacock MUST be in the OPEN position.
Running the pump dry may cause damage to
the unit.
Raw Water System
Fig. 3.11.1
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
34 GAL (129 L) LIVEWELL
LIVEWELL TANK PLUGS (2)
DELUXE LEANING POST (OPTION)
LIVEWELL DRAIN TO PORT DRAIN LINE
LIVEWELL SEACOCK
12V/800 GPH RAW WATER PUMP
FLOW ADJUSTMENT VALVE
LIVEWELL FILL
TANK OVERFLOW (LOW LEVEL)
TANK OVERFLOW (UPPER LEVEL)
Содержание 270 Outrage
Страница 28: ...1 20 270 Outrage Section 1 Safety R THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 48: ...2 20 Section 2 General Information 270 Outrage R THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 72: ...3 24 270 Outrage Section 3 Systems Components Overview Operation R THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 79: ...4 7 Section 4 Electrical System 270 Outrage R ConsoleWiringDiagram Fig 4 7 1 ...
Страница 80: ...4 8 270 Outrage Section 4 Electrical System R HullWiringDiagram Fig 4 8 1 ...
Страница 81: ...4 9 Section 4 Electrical System 270 Outrage R BreakerPanelWiringDiagram Fig 4 9 1 ...