![Whale INSTANT MATCH PREMIUM SDP303T Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/whale/instant-match-premium-sdp303t/instant-match-premium-sdp303t_installation-manuallines_967137020.webp)
INSTANT MATCH Kit Fault Diagnosis
Pump will not start
What is the fault?
Pump will not stop
NO
YES
Check unswitched spur connections are
good and insulation has not been pinched.
Check fuses and RCDs are ok.
If no obvious fault, attach plug to
transformer mains lead and plug into
known good socket.
Does lamp illuminate?
Check the
dwelling wiring,
fuses and RCDs.
If 10 - 20v on pump terminals
re-check polarity on pump.
If correct change
the pump (SDS021T)
Replace transformer
SDS233T (755.617)
Cut off spade connectors
and reconnect with
connector block, RED
to RED and BLK to BLK.
Retest. Does pump work?
No further action
Does pump start when TEST
button is pressed & released?
Ensure power is connected and switched on.
Press the TEST button on top of the transformer.
Does the buzzer beep?
NO
YES
NO
NO
YES
YES
NO
The transformer allows the pump to
over-run for up to 60 seconds.
If the pump continues to run after this
time has elapsed, switch off the
transformer at the mains and allow it to
cool and re-set. If this does not solve
the problem, replace transformer
SDS233T (755.617).
WIRED
Check transformer setting
is correct for sensor.
Check signal cable between sensor
and transformer is less than 5m
long, undamaged and that
connections are good.
Retest. Does pump work?
YES
Replace sensors
20