![Whale INSTANT MATCH PREMIUM SDP303T Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/whale/instant-match-premium-sdp303t/instant-match-premium-sdp303t_installation-manuallines_967137011.webp)
• Connect your sensor to the correct terminal block
(see illustration to the right).
• Gently tug on the sensor wires to ensure that there
is a secure connection.
• Connect mains wire to a 5A fused spur.
• The transformer is factory set as shown to the right on
the jumper settings for the Sika sensors, 30 seconds
overrun and 22mm inlet pipe size. For other settings
please refer to Transformer settings (see page 13).
• Refit the hatch and tighten the screws to make
the transformer water resistant.
6. Wiring your transformer (continued)
WHITE
GREEN
BROWN
• The blue LED flashes every 10 seconds indicating
that power is on.
• The green LED flashes when water is flowing
through the sensors.
• When the test button is depressed the buzzer beeps.
7.
The Whale Instant Match
®
Premium
transformer includes Activelink
diagnostics to aid installation:
On the transformer are two indicator LEDs
WITH
WHITE
GREEN
BROWN
11