GENERAL INFORMATION
WF-68100 Series Converter-Charger Safety Features

 

Reverse Battery Protection

The WF-68100 Series Converter-Chargers will charge the 12-volt house battery if installed. A 

battery does not have to be installed for WF-68100 Series Converter-Chargers operation. When 

a battery is installed, three reverse polarity fuses are installed to protect the converter circuitry. 

The fuses are located on the rear panel of the enclosure near the AC power cord (refer to Figure 

1 below). This feature prevents permanent damage to the converter from a battery connected 

into the circuit backwards. In addition to protecting the converter-charger, the reverse polarity 

fuses are the main connection between the converter-charger and the DC fuse board of a 

distribution center.

Содержание WF-68100 Series

Страница 1: ...he U S A and Canada by ARTERRA DISTRIBUTION 877 294 8997 Warranty warranty wfcoelectronics com Fax 574 294 8698 www wfcoelectronics com Power PROs Technical Support 877 294 8997 WF 9900 Series Deckmount Converter Charger WF 68100 Series ...

Страница 2: ... 5 OPERATIONAL FEATURES Three Stage Smart Charging 6 Front Panel Features 6 TROUBLESHOOTING INSTRUCTIONS Converter Output Voltage 8 Reverse Polarity Fuses 8 Battery Select Switch 9 Troubleshooting Flow Chart 9 GENERAL COMPLIANCE INFORMATION Agency Listings 9 INSTALLATION INSTRUCTIONS Mounting the Enclosure 10 DC Connections 10 AC Connections 11 SPECIFICATIONS 12 WARRANTY INFORMATION 13 TABLE OF C ...

Страница 3: ...battery is installed three reverse polarity fuses are installed to protect the converter circuitry The fuses are located on the rear panel of the enclosure near the AC power cord refer to Figure 1 below This feature prevents permanent damage to the converter from a battery connected into the circuit backwards In addition to protecting the converter charger the reverse polarity fuses are the main c...

Страница 4: ...s the unit from excessive heat that may damage sensitive components The unit will restart once the temperature inside has dropped Electronic Current Limiting In the event that the output current exceeds the maximum rating for the WF 68100 Series Converter Charger the output current will remain constant but the output voltage will begin to drop If this occurs the unit will recover once loads are re...

Страница 5: ...Engineering Three Stage Charging is Better WFCO s automatic three stage converters handle every charging need for the RV while extending the battery s life Well maintained batteries should never need more than two stage Normal and Trickle charging Our third stage Bulk is provided for the rare times a battery needs extra power for charging RVs are frequently sold with at least one 12 VDC accessory ...

Страница 6: ...oad connected to the converter will charge the battery to its fully charged level of 12 7 VDC in fewer than three hours Adding more DC loads will lessen the amount of current available and will lengthen the time required to charge the battery Batteries with damaged cells will also require additional time to charge and may never reach a full charge voltage Because of the relationship between voltag...

Страница 7: ...he output of the converter from 13 6 VDC to 13 2 VDC This lower voltage will keep the battery charged while the RV is not in use This also helps preserve the life of the battery while keeping it charged and ready for use A change in DC current will cause the converter to exit Float Mode and return to the default or normal Absorption Mode Note The converter while in Float Mode will continue to supp...

Страница 8: ...DC or if the battery is not charging check for an open inline fuse in the battery wire circuit One may have been installed by the RV manufacturer Also check for loose wiring connections Reverse Polarity Fuses If there is no DC output coming from the WF 68100 Series Converter Charger output lugs first check the reverse polarity fuses on the rear panel Then visually inspect the fuses for any breaks ...

Страница 9: ... The WF 68100 Series Converter Chargers are UL Listed and cUL Listed Canadian FCC Compliance Class B NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment...

Страница 10: ...d be selected to prevent excessive heat water moisture dust and dirt entering the unit installed As a rule allow a minimum of two cubic feet of clear airspace and or any additional venting as necessary to prevent the unit from overheating The front of the enclosure should not be obstructed to allow free air flow for the cooling fan Figure 6 An 8AWG copper conductor shall be used to bond the WF 681...

Страница 11: ...ft of the rear panel fan Due to the higher current required from the AC line to produce the high DC current output a 20 Amp power plug is provided The 20 Amp plug and corresponding receptacle are shown in Figure 7 below The 20 Amp receptacle must be wired back to the fuse box using 12AWG wire minimum Figure 7 ...

Страница 12: ...12 Figure 8 ...

Страница 13: ...t not limited to inconvenience loss of service loss of revenue loss or damage to personal property cost of all services performed in removing or replacing the WFCO product Specifications are subject to change without notice or obligation Any WFCO Electronics products sold through unauthorized Internet sources Example eBay will be excluded from all warranty coverage offered by Arterra Distribution ...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ...W F C O E L E C T R O N I C S C O M ...

Отзывы: