When the application is executed, it will display watchdog information in
the WATCHDOG INFORMATION group box. It displays max timeout, min
timeout, and timeout steps in milliseconds. For example, a 1~255 seconds
watchdog will has 255000 max timeout, 1000 min timeout, and 1000
timeout steps. You can test the functionality of the watchdog as follows:
n
Set the timeout value 3000 (3 sec.) in the SET TIMEOUT field and
set the delay value 2000 (2 sec.) in the SET DELAY field, then click
the START button. The Timeout Countdown field will countdown the
watchdog timer and display 5000 (5 sec.).
n
Before the timer counts down to zero, you can reset the timer by
clicking the REFRESH button. After you click this button, the
Timeout Countdown field will display the value of the SET TIMEOUT
field.
n
If you want to stop the watchdog timer, you just click the STOP
button.