10
Operation
The LED spotlight must be protected on the sub-distribution
board by a 10/16A fuse. An earth leakage circuit breaker must be
installed before this (FI protective switch).
The LED spotlight must be disconnected from the power supply
during installation. It is
not
sufficient to just turn off at the light
switch!
Turn the power off by removing the corresponding circuit fuse or
switch off at the circuit breaker. Secure it against an unauthorised
re-start, e.g. with a danger sign. In addition, switch off the associ-
ated earth-leakage circuit breaker.
Check that the mains connection is current free with a suitable
tester.
The earth protection cable must be connected when installing the
LED spotlight.
Do not install the LED spotlight, if the LED spotlight is replacing
an existing light and there is no protective earth cable available.
First, draw a new mains cable.
Where the protective earth is not connected, a fault with the
mains voltage might result in the metal housing of the LED spot-
light becoming live. There is a risk of a life-threatening electric
shock!
Содержание 80 35 68
Страница 3: ...III bersicht Overview 2 3 4 5 6 7 1...