4
Technical Data
Changing the Illuminant
Unplug from power mains before replacing the illuminant!
1. To replace the illuminant, remove the 6 rubber caps (7) and unscrew the
cross slot screws, situated at the rear side of the work lamp. Use this work
lamp only with the intended illuminant, a 2D fluorescent tube 230 V 28 W. A
replacement illuminant can be ordered from Westfalia under the article num-
ber 56 76 51.
2. Do not touch the illuminant and the transparent cover with bare hands in
order to avoid finger prints.
3. Retighten the screws hand tight and insert the rubber caps into the provided
holes.
Maintenance, Cleaning and Storing
Do not clean the work lamp with aggressive chemicals in order not to damage the
surfaces. Use only a moistened cloth for cleaning.
Store the work lamp in a dry place and protect the unit from dust and dirt.
Technical Data
Disposal of the Illuminant
Do not discharge the illuminant in the garbage bin, but
check with your local council for recycling facilities in your
area.
Please dismount the illuminant from the work lamp and
dispose of the work lamp separately.
Power Supply
230 V~ 50 Hz
Power
1 x 28 W
Illuminant
Fluorescent Lamp 2D max. 28 W 4 Pin GR8 Socket
Lumen Output
1666 Lumen
Power Cord
280 cm
Содержание 55 69 51
Страница 1: ...Westfalia Bedienungsanleitung Nr 106731...
Страница 4: ...III bersicht Overview 1 2 3 4 6 5 7...