Operation
11
Button Cells
1. For testing a button cell, insert the battery in the slot on the
side of the unit. Make sure the negative (-) pole is facing up.
2. Press down the brown switch on the front panel.
Do not push the brown switch when using the probe tips to
test a button cell. The button cell might be damaged by
doing this.
Do not allow the red probe tip (+) to contact the black probe
tip (-) when using the 9 V contacts to test button cells.
Operation – The Scale
1. Read the analogue display to determine the condition of the
battery.
Use the upper scale REGULAR for measuring regular zinc
carbon and alkaline batteries.
Use the centre scale BUTTON CELL-LITHIUM for
measuring mercury, silver oxide, alkaline and lithium button
cells.
Use the lower scale NICKEL CADMIUM for measuring
rechargeable nickel cadmium batteries.
2. The battery needs to be replaced (or recharged) if the indicator
needle is in the red “REPLACE” zone. The battery has
sufficient capacity left if the needle ends up in the green
“GOOD” zone. Consider replacing the battery if the needle
stops between the oblique lines of the REGULAR scale.
Zero Position Screw
The needle should be aligned with the black dot on the far left-
hand side of the upper scale when no batteries are being tested. If
not, adjust the zero position by turning the zero-position screw on
the front panel by using a suitable screwdriver.