- 8 - 

Installation 

5.  To connect a product tank level switch to the GRO unit, 

BE SURE THAT ALL POWER IS OFF!

  

Open the electrical control box and remove the jumper between terminals 1 and 2.  Connect the 

level switch between these terminals. 

 

The G-RO unit may be operated manually without the use of a level switch. 

 

 

Carbon Tank 

 

1.  (If a carbon tank is to be used for chlorine removal) With the carbon tank disconnected from the 

GRO unit, allow water to slowly fill the tank from the reverse direction, i.e., outlet to inlet, to 

initially rinse the carbon.  Run the water through the tank in this manner for 15 minutes, directing 

the water to drain.   

2.  Connect the tank from the inlet to outlet and run the water through the tank for an additional 5-

minute rinse to drain.   

 

Failure to follow backwash and rinse the carbon tank, as described above, will 

allow carbon to enter the RO membrane assembly and block the water 

passages, causing early system failure or degraded performance. 

 

3.  If a manual or automatic carbon tank is used for chlorine removal, use the backwash mode for 

an additional 5 minutes rinse to drain. 

 

Do NOT replace the 5 micron pleated cartridge with an activated carbon cartridge.  

An activated carbon cartridge does not have enough surface area to effectively 

remove all of the chlorine in the feedwater.  Severe pressure drops may also occur, 

causing the unit to continuously cycle on and off and damage the pump. 

Содержание GRO

Страница 1: ...mo os si is s W Wa at te er r T Tr re ea at tm me en nt t S Sy ys st te em m I I N N S S T T A A L L L L A A T T I I O O N N O O P P E E R R A A T T I I O O N N A A N N D D M M A A I I N N T T E E N N...

Страница 2: ...this manual The Seller reserves the right to make enhancements or changes that may not be included in the manual Therefore it is understood that the material presented here is subject to change withou...

Страница 3: ...y Electricity and water DO NOT MIX Every effort is made to insure that the electrical equipment on our systems is resistant to water intrusion Once installed the system is subject to many factors beyo...

Страница 4: ...nts Section Page System Specifications 5 Installation 6 Operation 9 System Maintenance 10 Cleaning 12 Troubleshooting 14 Drawings GRO 150 700 RO PSI Diagram GRO 150 700 RO Unit Layout GRO 150 700 Elec...

Страница 5: ...2 1 97 3 8 1 4 1 4 Note 1 Product flow is the MAXIMUM recommended flow 2 Reject flow is the MINIMUM recommended flow 3 Pump pressure must not exceed 200PSI 13 4 Bar Typical Operating Parameters SPECIF...

Страница 6: ...zes a booster pump in an enclosed area be sure that there is adequate ventilation to dissipate the heat from the motor Otherwise the heat buildup can weaken the plastic tubing and may cause it to burs...

Страница 7: ...atic carbon filter is used it should be set to regenerate when the RO unit is not running usually at night Hookups 1 Supply Connect the carbon filter to the GRO unit at the prefilter using non corrosi...

Страница 8: ...irecting the water to drain 2 Connect the tank from the inlet to outlet and run the water through the tank for an additional 5 minute rinse to drain Failure to follow backwash and rinse the carbon tan...

Страница 9: ...ortant when determining the system s performance over time For the most accurate TDS readings let the GRO unit run for at least 15 minutes Unit Shutdown The standard GRO system with no options is turn...

Страница 10: ...Feed water temperature should be kept below 100 degree F 37 5 degrees C Membranes Always keep moisture in the membrane pressure vessel and always keep the ends plugged be careful not to cross thread o...

Страница 11: ...r sequester calcium carbonate ferrous iron and calcium sulfate from the feed water via water softening or an anti scalant chemical feed system Use test kit to check water quality Follow these basic gu...

Страница 12: ...n at 25 degrees C 2 TDS level increase As the TDS Total Dissolved Solids level climbs the amount of water passing through the membrane decreases If the TDS level has climbed since the time of installa...

Страница 13: ...he cleaning solution mix sodium hydroxide NaOH with RO product water 2 gallons of water per membrane to obtain a 0 1 solution pH 11 12 30 degrees C maximum water temperature 3 Once the solution is mix...

Страница 14: ...R possible reasons 1 O ring by pass on membranes 2 Chlorine damage to membranes 3 Temperature increase 4 Reverse flow through membrane causing a rupture in the membrane PERMEATE TDS TOO HIGH possible...

Страница 15: ...15...

Страница 16: ...16 Rev 4 October 2018...

Отзывы: