background image

 
 
 

5NUD5 

Westward Operating Instructions and Parts Manual 

 

  

 
 
 

Lever Action Bucket Pump

 

General Safety Information  

Always wear safety glasses when using Lever Action 
barrel pump. Keep work area clean and remove any 
excess grease from tools, hands, and clothing after 
use. Do not use barrel pump whip hose for other 
applications or at pressure levels above rated 
pressures. 

 

If excess oil is left on the floor, 

tools or equipment, a slippery surface will be 
created.  

 

Never use this pump with water 

based fluids, chemicals and acids.

 

 

NOTE:

 The pump is made form plated steel 

components. It should never be used to transfer fluids 
that may cause the pump to rust. 

Pump comes complete with fuel resistant PVC 
Hose with Steel spout, Drum cover & pump units. 

Assembly

 

1. Make sure that the drum cover sits firmly on the  

container. Tighten the 3 thumb screws onto  
the drum cover assembly  to fix the drum cover 
firmly on to the container.  

Note:

 Tighten the thumb screw evenly on to the 

container (only hand tightens the thumb screws). 
 

2. Pull the plunger rod of piston sub assembly up  

and attach the lever handle to the piston rod using  
the pivot pin and retainer clip. 
 

3. Push the pump tube assembly through the die cast 

flange of the drum cover and push down until the 
pump tube rests on to the base of the container.  

Note:

 make sure the tube assembly touches the base 

of the container 
 

4. Tighten the machine screw and the hex nut in the 

flange assembly to hold the pump assembly firmly in 
place.  

 

Note:

 Do not over tighten the screw and nut. 

 
5. Screw the adapter on to the outlet pump head.  
 

Note:

 Do not  over tighten the adapter & use a thread 

sealant to prevent leakage. 

 
6. Screw on the hose assembly with hose clamp on to 

the other end of the adapter fitted on the pump head. 

Note:

 Make sure the hose clamp is firmly seated over 

the hose assembly and adapter. 

 

Operation 

1.  Start the pump by moving the lever handle. 
 
2.  If the pump needs priming put some oil in the hose 

outlet of the pump and start operating the lever 
handle. 

 

3.   While installing the pump pierce open the hole on 

the drum cover using a pin punch. 

 

4.  When the pump is not in use, place the hose 

assembly in to the hole provided on the drum cover. 

 

5.  Lever handle has 3 holes for attaching to the 

connecting lever.  Pump connecting lever comes 
pre-fitted in the middle hole of lever handle. 
Position of this can be  changed easily with help of 
retainer clip based on viscosity of fluid used , which 
facilitates ease of use. 

 
Wetted components 

Steel, Aluminum, Zinc, Brass, NBR, PVC 

 
Recommended Use 

Transmission, differentials and heavier oils 
 

Do not use with  

Water based & other corrosive media

 
 
 
 

Warranty 

 

LIMITED ONE-YEAR WARRANTY

 

Should this product fail to perform satisfactorily due to a defect or poor workmanship within ONE YEAR from the date 
of purchase, return it to the place of purchase and it will be replaced, free of charge. Incidental or consequential 
damages are excluded from this warranty.  

 