Portable Air Compressor
15- ENG
Westward Operating Instructions and Parts Manual
Model 3JR71
To Drain Tank (continued)
Water will
condense in the air
tank. If not drained, water will
corrode and weaken the air tank
causing a risk of air tank rupture.
6. After the water has been drained,
close the drain valve (clockwise).
The air compressor can now be
stored.
NOTE
: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, the
reinstalled.
MOTOR
The motor has an automatic reset
thermal overload protector. If the
motor overheats for any reason, the
overload protector will shut off the
motor. The motor must be allowed to
cool down before restarting. The
compressor will automatically restart
after the motor cools.
If the overload protector shuts the
motor off frequently, check for a
possible voltage problem. Low
voltage can also be suspected when:
1. The motor does not get up to full
power or speed.
2. Fuses blow out when starting the
motor; lights dim and remain dim
when motor is started and is
running.
AIR COMPRESSOR PUMP INTAKE
AND EXHAUST VALVES
Once a year have a trained service
technician check the air compressor
pump intake and exhaust valves.
AIR FILTER INSPECTION AND
REPLACEMENT
Hot surfaces. Risk
of burn.
Compressor heads are exposed
when filter cover is removed.
Allow compressor to cool prior to
servicing.
Keep the air filter
clean at all times.
Do not operate the air compressor
with the air filter removed.
A dirty air filter will not allow the
compressor pump to operate at full
capacity. Before you use the
compressor pump, check the air filter
to be sure it is clean and in place.
If it is dirty, replace it with a new filter.
On some models,the filter may be
removed by using a pair of needle
nose pliers or a screwdriver. Pull or
pry out the old filter and carefully
clean the filter area. Push in the new
air filter.
Service and Adjustments
Unit cycles
automatically when
power is on. When doing
Maintenance, you may be exposed
to voltage sources, compressed air
or moving parts. Personal injuries
can occur. Before performing any
Maintenance or repair, unplug the
compressor and bleed off all air
pressure.
ALL MAINTENANCE AND REPAIR
OPERATIONS NOT LISTED MUST
BE PERFORMED BY A TRAINED
SERVICE TECHNICIAN.
Содержание 3JR71
Страница 28: ...28 ENG Westward Operating Instructions and Parts Manual Model 3JR71 Portable Air Compressor ...
Страница 56: ...56 SP Westward Instrucciones operativas y manual de piezas Modelo 3JR71 Compresor portátil de aire ...
Страница 84: ...84 SP Westward Instrucciones operativas y manual de piezas Modelo 3JR71 Compresor portátil de aire ...