INCLUDED   PARTS

   

The   Vibralung   AcousEcal   Percussor   is   supplied   in   two   boxes

.       

One   box   holds   the   reusable   Treatment   Control   Unit   (A),   

Pole-­‐mount   Bracket   (B),   and   BaYery   Charger   (C).      The   other   box   holds   the   disposable   Hand-­‐held   Transducer   assembly   (D)   

plus   Standard   Y-­‐adapter,   mouthpiece   and   Variable   Expiratory   Resistor   (E),   plus   an   Aerosol   Y-­‐adapter   (F)   that   can   be   used   

for   aerosol   delivery.      You   should   have   all   the   following   parts   (images   not   to   scale):   

Treatment   Control   

Unit   (TCU)   

      BaQery   

Charger   

Standard   Y-­‐adapter   

Aerosol   Y-­‐adapter   

Pole-­‐mount   Bracket   

(pole   not   included)   

A"

!

!

!

!

!

!

!

!

!

!

B"

C"

D"

E"

!

!

!

!

!

!

!

!

!

!

F"

!

Hand-­‐held   Transducer   (HHT)   

A   cable   (not   shown)   emerges   from   

the   boYom   of   the   handle   for   

connecEng   the   HHT   to   the   TCU   

Mouthpiece   

Inspiratory   

Valve   

(purple   cap)   

Variable   

Expiratory   
Resistor   
for   PEP   

Screw-­‐on   Cone   

PREPARING   THE   TCU   FOR   FIRST   USE   

Page   3   

Follow   these   steps   to   charge,   test   and   set   up   the   Treatment   Control   Unit   (TCU)   for   the   first   (me.      

         

1.

Remove   the   TCU   (A),   Pole-­‐mount   Bracket   (B)   and   BaYery   Charger   (C)   from   their   shipping   box.   

2.

Mount   the   TCU   on   any   pole   between   ¾   and   1¼   inch   in   diameter   using   the   supplied   Pole-­‐mount   Bracket   as   shown   in   

the   figure   above.      Alternately,   simply   set   the   TCU   on   a   flat   surface.   

3.

Plug   the   BaYery   Charger   into   a   standard   120   volt   electrical   outlet   and   plug   the   end   of   the   baYery   charger   cable   into   

the   boYom   jack   on   the   len   side   of   the   TCU.      (The   BaYery   Charger   plug   will   not   fit   in   the   top   jack   on   the   len   side   of   

the   TCU).      All   9   Light   Emipng   Diodes   (LEDs)   should   flash   3   Emes   quickly   and   then   the   Charging   and   Power   LEDs   

should   stay   on   during   the   charging   process.      

4.

Leave   the   BaYery   Charger   plugged   in   and   connected   to   the   TCU   unEl   the   TCU’s   internal   baYeries   are   fully   charged   

(which   should   take   no   more   than   4   hours).      The      Charging   LED   will   go   out   and   the   Power   LED   will   flash   when   the   

unit   is   fully   charged.   

5.

Disconnect   the   BaYery   Charger   aner   baYeries   are   charged,   as   the   TCU   will   not   operate   while   the   charger   is   

connected.      

6.

Aner   charging   is   completed   and   the   charger   is   disconnected   from   the   TCU,   perform   a   Power   On   Self   Test   (POST)   to   

verify   that   the   TCU   sonware   and   processor   is   operaEng   properly:   Turn   the   TCU   on   by   pressing   the   Power   control   

buYon   once.   The   POST   will   occur   immediately   as   shown   by   all   9   LEDs   flashing   3   Emes.   If   the   TCU   passes   the   POST,   

the   Pause   and   Power   LEDs   will   remain   illuminated.      If   other   LEDs   are   illuminated,   or   if   no   LEDs   are   illuminated,   the   

TCU   failed   the   POST   and   should   not   be   used.   Contact   Westmed   Customer   Service   (see   page   10).   

7.

The   Treatment   Control   Unit   (TCU)   is   now   ready   for   use.      Repeat   these   steps   every   Eme   the   baYery   needs   to   be   

recharged,   as   indicated   by   the   Low   BaYery   LED.   

Handle   

Содержание Vibralung Acoustical Percussor

Страница 1: ...Contraindica ons ACT or use of the Vibralung AcousEcal Percussor especially with PosiEve Expiratory Pressure may be contraindicated in paEents who have untreated air leaks tension pneumothorax bronch...

Страница 2: ...gs during each treatment Do not connect or interface the Vibralung AcousEcal Percussor to any airway clearance device or aerosol delivery system other than the Westmed Circulaire II or Circulaire II H...

Страница 3: ...andard 120 volt electrical outlet and plug the end of the baYery charger cable into the boYom jack on the len side of the TCU The BaYery Charger plug will not t in the top jack on the len side of the...

Страница 4: ...n or compressed air Adjust the opening of the Variable Expiratory Resistor to apply PEP See the Circulaire II or Circulaire II Hybrid package insert for further instrucEons for use Bird s Eye View HHT...

Страница 5: ...as well as a Start Pause funcEon and Power On O AddiEonally two LED indicators Charging and Low BaYery illuminate as needed to show the status of the internal baYery Page 5 Connect HHT here Connect Ba...

Страница 6: ...de 3 Resume Terminate Repeat To resume an automaEcally terminated session or repeat a session with the same sepngs or start a di erent session with di erent sepngs repeat steps 1 and 2 above and selec...

Страница 7: ...ng the Circulaire II Hybrid to the HHT as shown in the boYom gure on page 4 The Circulaire II Hybrid when aYached to the Vibralung AcousEcal Percussor with the Aerosol Y adapter provides a direct path...

Страница 8: ...Page 8 TROUBLESHOOTING conEnued next page...

Страница 9: ...o minimize surface contaminaEon Clean all external surfaces of the TCU with a pre moistened germicidal wipe product such as Clorox DisinfecEng Wipes Be sure to allow the appropriate contact Eme as spe...

Страница 10: ...Page 10 TECHNICAL SPECIFICATIONS conEnued next page...

Страница 11: ...Page 11 TECHNICAL SPECIFICATIONS...

Страница 12: ...Page 12 ELECTROMAGNETIC EMISSIONS AND ENVIRONMENT...

Страница 13: ...placing its internal baYeries or replacing the enEre TCU To iniEate a service request please contact the Westmed Customer Service Department and request a Returned Goods AuthorizaEon RGA Number prior...

Страница 14: ...mark of Westmed Inc Circulaire II Hybrid is a trademark of Westmed Inc PN 71944 Rev 01 Westmed Inc 5580 S Nogales Highway Tucson AZ 85706 800 975 7987 www westmedinc com For further informa on scan th...

Отзывы: