SERVICE   

For   any   unexpected   change   in   normal   operaEon,   suspected   malfuncEon,   or   failure   of   the   device,   

contact   the   Westmed   Customer   Service   Department   at   the   telephone   number   below.   

Prior   to   considering   service,   be   sure   to   review   the   TroubleshooEng   secEon   above.   

Only   the   Treatment   Control   Unit   (TCU)   can   be   serviced.   There   are   no   serviceable   parts   in   the   disposable   

Hand-­‐held   Transducer   (HHT).   

Westmed,   Inc.   is   the   only   authorized   service   center   available   for   diagnosing   or   repairing   the   Vibralung   

AcousEcal   Percussor   TCU,   replacing   its   internal   baYeries,   or   replacing   the   enEre   TCU.   

To   iniEate   a   service   request,   please   contact   the   Westmed   Customer   Service   Department   and   request   a   

Returned   Goods   AuthorizaEon   (RGA)   Number   prior   to   returning   the   device(s)   for   service.      

Place   the   RGA   Number   on   the   outside   of   the   shipping   package   when   returning   goods   to   Westmed.   

Any   device   received   by   Westmed   without   an   RGA   Number   will   be   returned   to   sender.   

When   packaging   for   return,   please   perform   disinfecEon   on   the   TCU   according   to   the   Care   and   Cleaning   

InstrucEons   on   page   9,   then   place   it   in   a   plasEc   bag   and   surround   with   packaging   peanuts,   bubble   wrap   or   

crushed   paper   for   addiEonal   protecEon.   

Westmed,   Inc.   /   Customer   Service

   

5580   South   Nogales   Highway

   

Tucson,   AZ   85706-­‐3333

   

(800)   975-­‐7987   

   

Содержание Vibralung Acoustical Percussor

Страница 1: ...Contraindica ons ACT or use of the Vibralung AcousEcal Percussor especially with PosiEve Expiratory Pressure may be contraindicated in paEents who have untreated air leaks tension pneumothorax bronch...

Страница 2: ...gs during each treatment Do not connect or interface the Vibralung AcousEcal Percussor to any airway clearance device or aerosol delivery system other than the Westmed Circulaire II or Circulaire II H...

Страница 3: ...andard 120 volt electrical outlet and plug the end of the baYery charger cable into the boYom jack on the len side of the TCU The BaYery Charger plug will not t in the top jack on the len side of the...

Страница 4: ...n or compressed air Adjust the opening of the Variable Expiratory Resistor to apply PEP See the Circulaire II or Circulaire II Hybrid package insert for further instrucEons for use Bird s Eye View HHT...

Страница 5: ...as well as a Start Pause funcEon and Power On O AddiEonally two LED indicators Charging and Low BaYery illuminate as needed to show the status of the internal baYery Page 5 Connect HHT here Connect Ba...

Страница 6: ...de 3 Resume Terminate Repeat To resume an automaEcally terminated session or repeat a session with the same sepngs or start a di erent session with di erent sepngs repeat steps 1 and 2 above and selec...

Страница 7: ...ng the Circulaire II Hybrid to the HHT as shown in the boYom gure on page 4 The Circulaire II Hybrid when aYached to the Vibralung AcousEcal Percussor with the Aerosol Y adapter provides a direct path...

Страница 8: ...Page 8 TROUBLESHOOTING conEnued next page...

Страница 9: ...o minimize surface contaminaEon Clean all external surfaces of the TCU with a pre moistened germicidal wipe product such as Clorox DisinfecEng Wipes Be sure to allow the appropriate contact Eme as spe...

Страница 10: ...Page 10 TECHNICAL SPECIFICATIONS conEnued next page...

Страница 11: ...Page 11 TECHNICAL SPECIFICATIONS...

Страница 12: ...Page 12 ELECTROMAGNETIC EMISSIONS AND ENVIRONMENT...

Страница 13: ...placing its internal baYeries or replacing the enEre TCU To iniEate a service request please contact the Westmed Customer Service Department and request a Returned Goods AuthorizaEon RGA Number prior...

Страница 14: ...mark of Westmed Inc Circulaire II Hybrid is a trademark of Westmed Inc PN 71944 Rev 01 Westmed Inc 5580 S Nogales Highway Tucson AZ 85706 800 975 7987 www westmedinc com For further informa on scan th...

Отзывы: