INSTALLATION

Standard ducting installation

It is recommended that the unit be positioned at a 
minimum of 600mm for an electric cooktop and 650mm 
for a gas cooktop, and no further from the cooktop than 
800mm. Then unit becomes less effective as the distance 
from the cooking surface to the rangehood increase.

 

650

GAS

ELECTRIC

600

Fixing point dimensions – WRR626SB

 

555

600

210

280

280

rear cover can be reversed  

to suit gap at rear

160

230

150

Fixing point dimensions – WRR926SB

 

855

900

210

280

280

rear cover can be reversed 

to suit gap at rear

160

230

150

 WARNING!

Failure to install the screws or fixing device in 
accordance with these instructions may result in 
electrical hazards.

Parts supplied with hood

1 x Ø 150mm air outlet
1 x Ø 150mm to Ø 120mm converter
2 x rear covers
2 x lateral covers
6 x self tapping screws 3 x 12mm
2 x self tapping screws 3.5 x 10mm
4 x Ø 6  washers
4 x M6 x 40 screws
2 x carbo
2 x air intake grilles

Parts to be purchased

  Aluminium tape or cable ties to secure flue pipe

  Ducting accessories 

Drilling holes

Drill the holes on top wooden support

  drill Ø 7mm hole

  drill Ø 16mm hole

  cut Ø 196mm hole

 

Ø

 7 for hood

fastening screws

86

Ø

 16 for cable

clearance

Ø

clearance

453/753

door/hood fascia

front of 

cabinet

33

210

272

252

192

Fixing the air outlet

Use screws to fix the air outlet to the rangehood.

 

ST 3.5 x 10

Fixing the lateral cover

Use screws to fix the lateral cover to the rangehood.

 

ST 3 x 12

underside of  

rangehood

top of cooking 

surface

if the cooktop 

manufacturer 

a greater 

clearance 

then that 

must be used

40

40

272

272

Содержание WRR926SB

Страница 1: ...USER MANUAL WRR626SB WRR926SB RANGEHOOD ...

Страница 2: ...ations such as Staff kitchen areas in shops offices and other working environments Farm houses By clients in hotels motels and other residential type environments Bed and breakfast type environments Catering and similar non retail applications CONTENTS 3 Important safety instructions 4 Installation 6 Operation and maintenance 7 Warranty RECORD MODEL AND SERIAL NUMBER HERE Model Serial No IMPORTANT...

Страница 3: ... when the rangehood is in use Always switch off gas burners before you remove pots or pans CAUTION Accessible parts may become hot when used with cooking appliance Regulations concerning the discharge of air have to be fulfilled Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards Cleaning Wipe the rangehood body and flue with a spon...

Страница 4: ...Parts supplied with hood 1 x Ø 150mm air outlet 1 x Ø 150mm to Ø 120mm converter 2 x rear covers 2 x lateral covers 6 x self tapping screws 3 x 12mm 2 x self tapping screws 3 5 x 10mm 4 x Ø 6 washers 4 x M6 x 40 screws 2 x carbo 2 x air intake grilles Parts to be purchased Aluminium tape or cable ties to secure flue pipe Ducting accessories Drilling holes Drill the holes on top wooden support dril...

Страница 5: ...uct with the wire helix pulled taut to minimise pressure and noise Ducting accessories WRR626SB WRR926SB For best performance Ø 150mm ducting is recommended Ø 125mm ducting can be used but will reduce the airflow of the cooker hood roof cowl AR150RC AR125RC AR150F AR125F AR150FD AR125FD AR125FJD with damper wall vent kit AR150WV AR125WV bend AR150FD AR125B for Ø 150 bend use 02825263 Accessories c...

Страница 6: ... clip on either side to release filter 3 Pull filter downwards to remove Repeat 2 3 for models with a second filter 4 Turn off mains switch before cleaning drawer and cooker hood body 5 Soak and agitate the filters in hot soapy water or washing soda Rinse drain and shake well The filters may also be placed in a dishwasher Please note that some discolouration may occur This will not affect the perf...

Страница 7: ...he Appliance caused by i negligence or accident ii misuse or abuse including failure to properly maintain or service iii improper negligent or faulty servicing or repair works done by anyone other than an Electrolux authorised repairer or ASC iv normal wear and tear v power surges electrical storm damage or incorrect power supply vi incomplete or improper installation vii incorrect improper or ina...

Страница 8: ...more information on all Westinghouse appliances or for dimension and installation information call into your retailer phone or email our customer care team or visit our website and WESTINGHOUSE are trademarks of Westinghouse Electric Corporation Used under license by Electrolux Home Products Pty Ltd All Rights Reserved 2019 Electrolux Home Products Pty Ltd ABN 51 004 762 341 WMAN_RetRangehood_Sep1...

Отзывы: