WESTINGHOUSE PACKAGE A/C MANUAL
R-410A : 220V: 60Hz
3
3. Nomenclature
4. Feature & Benefit
1. The adoption of anticorrosive-box
The reinforced anticorrosion by using galvanization armor plate and coated with man-composed paint.
The appearance is stylish and be easy for maintenance.
(It’s OK for 1000 hours salt spray test)
2. The adoption of credible protection system
2.1 The protection for compressor
High-pressure protection, low-pressure protection, compressor
current protection and so on the series’ protectors can ensure
compressor operating normally.
Adopts independent system, except for protections of sequence and
wire control output, any protection relate to its corresponding
compressor. Once a compressor protection energized, the
corresponding compressor will stop, others are still working.
2.2 Fan motor
The fan motors for evaporator have over-heat protection and
over-current protection function. The fan motors for condenser have the temperature controller
protection function.
W
P
A
X
H
150
K
A
2
D
WESTINGHOUSE - W
D - 13 SEER
MILLER - M
E - 14 SEER
OEM - O
Omit (Below 13 SEER)
Refrigerant Type
Rooftop Package Unit - P
2 - R-22
4 - R-410A
Two-way air outlet - A
Control Type
One way air outlet - Side - C
W - Wireless
A - Wired
S - No Control (Supplied Separately)
Cooling Only - X
Power Supply
Heat Pump - P
K - 208/230 V - 1 Ph - 60 Hz
C - 208/230 V - 3 Ph - 60 Hz
Y - 380 V - 3 Ph - 60 Hz
G - 380-415 V - 3 Ph - 50 Hz
Tropical / High Ambient (T3) - H
E - 220-240 V - 1 Ph - 50 Hz
Omit for T1 Condition
Nominal Cooling Capacity
060 - (000) Btu/h
Product Series
SEER Rating
Brand
Unit Type
Design Series
Function Type
Содержание WPAPH-090CA4
Страница 1: ...ROOFTOP PACKAGE A C SERVICE MANUAL R 410A 220VOLTS 60HZ...
Страница 19: ...WESTINGHOUSE PACKAGE A C MANUAL R 410A 220V 60Hz 18 7 2 7 5ton...
Страница 20: ...WESTINGHOUSE PACKAGE A C MANUAL R 410A 220V 60Hz 19 7 3 10 ton...
Страница 22: ...WESTINGHOUSE PACKAGE A C MANUAL R 410A 220V 60Hz 21 7 5 15 17 5ton...
Страница 23: ...WESTINGHOUSE PACKAGE A C MANUAL R 410A 220V 60Hz 22 7 6 20 ton...
Страница 42: ...WESTINGHOUSE PACKAGE A C MANUAL R 410A 220V 60Hz 41 10 Explode View WPAXH 060CA4...
Страница 45: ...WESTINGHOUSE PACKAGE A C MANUAL R 410A 220V 60Hz 44 WPAXH 090CA4...
Страница 52: ...WESTINGHOUSE PACKAGE A C MANUAL R 410A 220V 60Hz 51 WPAXH 120CA4...
Страница 59: ...WESTINGHOUSE PACKAGE A C MANUAL R 410A 220V 60Hz 58 WPAXH 150CA4...
Страница 62: ...WESTINGHOUSE PACKAGE A C MANUAL R 410A 220V 60Hz 61 WPAXH 180CA4...
Страница 65: ...WESTINGHOUSE PACKAGE A C MANUAL R 410A 220V 60Hz 64 WPAPH 180CA4...
Страница 69: ...WESTINGHOUSE PACKAGE A C MANUAL R 410A 220V 60Hz 68 WPAXH 205CA4...
Страница 75: ...WESTINGHOUSE PACKAGE A C MANUAL R 410A 220V 60Hz 74 WPAPH 240CA4...
Страница 94: ...WESTINGHOUSE PACKAGE A C MANUAL R 410A 220V 60Hz 93 Typical rooftop application with frame...