11
WHL-015 REV. 1.13.17
H. HIGH ELEVATION INSTALLATIONS
Natural gas at high elevation might contain less heating value than typical 1,000 BTU/cu ft and therefore can cause improper air / gas
mix leading to improper combustion. For natural gas installations above 3,000 ft, call your gas provider to determine the heating value
of the supplied natural gas.
PART 3 – TECHNICAL SPECIFICATIONS
MODEL
140F
199F
Installation
Indoor, Floor Stand, Fully Condensing
Minimum / Maximum Input
(Btu/Hr)
DHW
28,000 / 140,000
19,900 / 199,000
CH
19,900 / 140,000
AFUE
92.7%
95.7 %
Hot Water Capacity
35
o
F Rise
7.1 GPM
9.9 GPM
45
o
F Rise
5.5 GPM
7.7 GPM
77
o
F Rise
3.2 GPM
4.8 GPM
Flue System
Sealed Combustion Direct Vent, Power Vent
Combined Vent Length
2” (50 feet), 3” (100 feet)
Shipping Weight (lbs est.)
250
260
Orifice Size
NG
0.232” (5.9 mm)
0.327” (8.3 mm)
LP
0.185” (4.7 mm)
0.244” (6.2 mm)
Gas Supply Pressure
NG
3.5” to 14” WC
LP
3.5” to 14” WC
Manifold Pressure
Min (2” / 3” Vent)
NG/LP: 0” WC
NG/LP: -
0.015” WC
Max (2” / 3” Vent)
NG/LP: -
0.22” WC
NG/LP: -
0.134” WC / -0.173” WC
Power Supply
Main Supply
120V 60 Hz / 6A
Maximum Power
Consumption
160W
Ignition System
Direct Electronic Ignition / Automatic Flame Sensing
Burner System
Single Orifice Premixed Fuel Modulation Ceramic Fiber Infrared
Gas Valve System
Combination Modulating (Current Proportional)
Internal Pipe Material
Copper
Dimensions
W 15.7” – H 53” – D 26.8”
W 15.7” – H 53.7” – D 26.8”
Storage Tank Water Capacity (DHW)
Under 15 Gallons
Main Controller / Control Panel
GTX-920C / P-920C_CB-HTP
CH Pressure
Min 12 PSI - Max 30 PSI
DHW Pressure
Max 150 PSI
Connection
Sizes
DHW Inlet / Hot Water Outlet
¾” NPT
CH Supply / Return
1” NPT
Gas Inlet
½” NPT (1/2” X ¾” Bell Coupling
Provided to Upsize Gas Line)
3/4"NPT
Materials
Cabinet
Cold Rolled Carbon Steel
Heat Exchanger
Primary Heat Exchanger: Stainless Steel
Storage Tank: Stainless Steel
Safety Devices
Optical Flame Sensor, Burner Plate High Limit (392
o
F), Water Temperature High
Limit Sensor (200
o
F), Gas Leak Detection Sensor (Detects Natural Gas or
Propane), Freeze Protection (Three Stage Operation - Activates at 46
o
F
– See
Freeze Protection in Installer Menu for Details), Exhaust Temperature High Limit
Sensor (190
o
F), Blocked Flue Switch, Condensate Switch, Built-In Low Water
Cut-Off Probe
Table 4
–Technical Specifications – NOTE: 199F Models Offer a Maximum BTU/Hr Input of 140,000 as Shipped. Maximum
BTU/Hr can be increased up to 199,000 BTU/Hr with a Larger External Pump Installed in the Primary Loop
Содержание WBRC 140F Series
Страница 2: ...2 WHL 015 REV 1 13 17 ...
Страница 43: ...43 WHL 015 REV 1 13 17 Figure 29 140F Model Electrical Wiring Diagram ...
Страница 44: ...44 WHL 015 REV 1 13 17 Figure 30 140F Model Ladder Diagram ...
Страница 45: ...45 WHL 015 REV 1 13 17 Figure 31 199F Model Electrical Wiring Diagram ...
Страница 46: ...46 WHL 015 REV 1 13 17 Figure 32 199F Model Ladder Diagram ...
Страница 87: ...87 WHL 015 REV 1 13 17 MAINTENANCE NOTES ...