Westinghouse ETL-ES-Cassidy-WH16 Скачать руководство пользователя страница 2

2

ETL-ES-Cassidy-WH16

1.  Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70), including fire-rated construction.

2.  Use this unit only in the manner intended by the manufacturer.  If you have  any  questions contact the manufacturer.

3.  After making the wire connections, gently push connections into outlet box with wire nuts pointing up. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on 

 

one side of the outlet box and ungrounded conductor on the other side of the outlet box.

4.  Before you begin installing the fan, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.  When the service disconnecting means cannot be 

 

locked, securely fasten a prominent warning device, such  as a tag, to the service panel.

5.  Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

6.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

7.  Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.

8.  To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support, and use the mounting screws provided with the outlet box. (Mounting must 

 

support at least 35 lbs.)

9.  WARNING! Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.

10.  Attach the mounting bracket using only the hardware supplied with the outlet box. Fan is only to be mounted to an outlet box marked “Acceptable for Fan Support”. 

11.  WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

12.  If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

13.  NEVER place a switch where it can be reached from a tub or shower.

14.  The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as those 

 

published by the National Fire Protection Association (NFPA),  and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

15.  Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.  When the service disconnecting means cannot be 

 

locked, securely fasten a prominent warning device, such  as a tag, to the service panel.

16.  All set screws must be checked and re-tightened where necessary before installation.

17.    The appliance is not intended for use by young children or infirmed persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.

TOOLS REQUIRED

Phillips screwdriver         wire Cutters         Pliers        step ladder

safety tiPs

OBserVe tHe fOllOwinG: read and saVe tHese instruCtiOns

warninG: tO reduCe tHe risK Of fire, eleCtriC sHOCK, Or PersOnal inJury, MOunt tO Outlet BOX MarKed 'aCCePtaBle fOr fan suPPOrt Of 35 lBs (15.9 KG) Or less' and 

use MOuntinG sCrews PrOVided witH tHe Outlet BOX and/Or suPPOrt direCtly frOM BuildinG struCture. MOst Outlet BOXes COMMOnly used fOr tHe suPPOrt Of 

luMinaries are nOt aCCePtaBle fOr fan suPPOrt and May need tO Be rePlaCed. COnsult a Qualified eleCtriCian if in dOuBt.

Содержание ETL-ES-Cassidy-WH16

Страница 1: ...assidy WH16 Owner s Manual Manual del usuario Cassidy Please write model number here for future reference Por favor incluya el n mero del modelo aqu para futura referencia NetWeight 12 11 LBS Peso Net...

Страница 2: ...usingonlythehardwaresuppliedwiththeoutletbox Fanisonlytobemountedtoanoutletboxmarked AcceptableforFanSupport 11 WARNING Toreducetheriskoffireorelectricshock donotusethisfanwithanysolidstatefanspeedcon...

Страница 3: ...leforFanSupport Aceptableparasoportarventiladores 11 ADVERTENCIA Parareducirelriesgodeincendiosochoquesel ctricos nouseesteventiladorconundispositivodecontroldevelocidaddeestados lidoparaventilador ou...

Страница 4: ...requerir una varilla vertical m s larga se vende por separado FLUSH MOUNT INSTALLATION INSTALACI N ALTECHO For low ceilings Para techo bajos Features Caracter sticas Note For sloped ceiling installati...

Страница 5: ...NOTE Combo Blade finishes vary depending upon model ALETAS DE DOBLE CARA Lasaletasdelrotordedoblecarapresentandossuperficiesconunacabadodealtacalidad Invirtiendo lasaletasUd puedeproducirunefectodecor...

Страница 6: ...fan to wobble 2 pREPARING for installation Antes de la instalaci n Quite el envoltorio e inspeccione detenidamente el ventilador para verificar que todas las piezas est n incluidas Apague la alimenta...

Страница 7: ...hetwomatingholes 2 onthecanopy Loosen donotremove thescrewsinthematingslots 1 onthecanopy Rotatethemountingbracketandremove fromthecanopy Quitelostornillosdelosdosagujeroscoincidentes 2 deldosel Afloj...

Страница 8: ...If flush mount option is selected proceed to page 9 step 6 OPCI N DE INSTALACI N AL TECHO Si elige la opci n de montaje al techo proceda a la p gina 9 paso 6 NORMAL DOWNROD OPTION If installing downro...

Страница 9: ...llosdemontajeal techoylasarandelasdepresi nincluidas Aprietelostornillosasegur ndolos 7 Forflushmountoption raisefanassemblyandplaceontohookfrommounting bracketintoaclosedholeonthecanopy Thiswillallow...

Страница 10: ...edequeelagujerodelavarillaverticalyelde lahorquilladelavarillaverticalest nalineados Instaleelpasadortransversaldelahorquilla 1 pas ndoloporlahorquillaylavarillavertical Inserteelpasadordefijaci n 2 e...

Страница 11: ...f no pre drilled hole exists in the extended downrod tighten the set screw against the downrod to secure the downrod ball Vuelva a instalar el pasador en la varilla vertical m s larga y deslice la bol...

Страница 12: ...lmotoratrav sdelavarillavertical conjuntodeldoseleinsertelavarillaverticalenlahorquilladelamisma Aseg resedequeelagujero delavarillaverticalyeldelahorquilladelavarillaverticalest nalineados Instaleelp...

Страница 13: ...ionesdecableado 13 Carefully lift fan assembly onto mounting bracket Rotate fan until notch on downrod ball 1 engages the ridge on the mounting bracket 2 This will allow for hands free wiring Levante...

Страница 14: ...ventilador vivo Interruptor de la luz vivo Verde de tierra DelVentilador De La Casa conectar conectar conectar conectar Conecte el cable azul s lo si conecta un juego de luces al ventilador Control d...

Страница 15: ...dosel directamente abajo y en l nea con los dos tornillos del soporte de montaje 3 Eleve el dosel permitiendo que los dos tornillos se deslicen dentro de las ranuras Gire el dosel hasta que ambos tor...

Страница 16: ...aspl sticasdeembalajeparasosteneralmotorydesc rtelas Fije elconjuntodelasaletasalmotorusandolasjuntasreductorasdesonidodelmotor 1 lostornillosparaelmotor 2 ylasarandelas 3 incluidos Aprietelostornillo...

Страница 17: ...whitetowhiteandblueto black Attachlightkittotheswitchhousingusingthreescrews fromlaststep Installlightbulbs included Quitalelostornillosdelalojamientodelinterruptor guardalosparaelproximopaso conecte...

Страница 18: ...geramente de ambas cadenas en la pieza de uni n Light fixture installation Instalaci n del artefacto luminoso 21 Locate the indentations on the neck of the glass and align with the protrusions on the...

Страница 19: ...arm air off the ceiling area as shown in illustration B This allows you to set your heating unit on a lower setting without affecting your comfort NOTE Turn off and wait for fan to stop before changin...

Страница 20: ...e ascendente aleja el aire caliente del rea del ventilador de techo como lo indica la ilustraci n B Esto le permite ajustar la calefacci n a un nivel m s bajo sin que afecte su comodidad NOTA Apague e...

Страница 21: ...f the wobble Check for wobble after each step 1 Check that all blades are screwed firmly into blade holders 2 Check that all blade holders are tightened securely to motor 3 Make sure that canopy and m...

Страница 22: ...deber aneliminarlamayor adelosproblemasdeoscilaci n Verifiquelaoscilaci ndespu sdecadapaso 1 Verifique que todas las aletas est n firmemente atornilladas a los soportes de las aletas 2 Verifique que...

Страница 23: ...tch 6 Light Control Switch 7 Capacitor 8 Hardware Pack No Descripci n 1 Soporte de montaje 2 Soporte para aleta 3 Aleta 4 Pantalla de vidrio 5 Interruptor de control de velocidad para ventilador 6 Int...

Страница 24: ...ng Philadelphia PA 19154 1029 U S A www westinghouselighting com WESTINGHOUSE and INNOVATION YOU CAN BE SURE OF are trademarks of Westinghouse Electric Corporation Used under license by Westinghouse L...