Westinghouse 5300 Running Watts Скачать руководство пользователя страница 6

6 | Westinghouse Outdoor Power Equipment, LLC

DANGER

Never use the generator in a location that is wet or damp. Never expose the generator to rain, snow, water 

spray or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture 

or ice can cause a short circuit or other malfunction in the electrical circuit.

Never operate the generator in an enclosed area. Engine exhaust contains carbon monoxide. Only operate 

the generator outside and away from windows, doors and vents.

WARNING

Voltage produced by the generator could result in death or serious injury.

Never operate the generator in rain or a flood plain unless proper precautions are taken to avoid

being subject to rain or a flood.

Never use worn or damaged extension cords.

Always have a licensed electrician connect the generator to the utility circuit.

Never touch an operating generator if the generator is wet or if you have wet hands.

Never operate the generator in highly conductive areas such as around metal decking or steel works.

Always use grounded extension cords. Always use three-wire or double-insulated power tools.

Never touch live terminals or bare wires while the generator is operating.

Be sure the generator is properly grounded before operating.

WARNING

Gasoline and gasoline vapors are extremely flammable and explosive under certain conditions.

Always refuel the generator outdoors, in a well-ventilated area.

Never remove the fuel cap with the engine running.

Never refuel the generator while the engine is running. Always turn engine off and allow the generator

to cool before refueling.

Only fill fuel tank with gasoline.

Keep sparks, open flames or other form of ignition (such as match, cigarette, static electric source)

away when refueling.

Never overfill the fuel tank. Leave room for fuel to expand. Overfilling the fuel tank can result in a

sudden overflow of gasoline and result in spilled gasoline coming in contact with HOT surfaces.

Spilled fuel can ignite. If fuel is spilled on the generator, wipe up any spills immediately. Dispose of

rag properly. Allow area of spilled fuel to dry before operating the generator.

Wear eye protection while refueling.

Never use gasoline as a cleaning agent.

Store any containers containing gasoline in a well-ventilated area, away from any combustibles or

source of ignition.

Check for fuel leaks after refueling. Never operate the engine if a fuel leak is discovered.

WARNING

Never operate the generator if powered items overheat, electrical 

output drops, there is sparking, flames or smoke coming from the 

generator, or if the receptacles are damaged.

Never use the generator to power medical support equipment.

Always remove any tools or other service equipment used during 

maintenance from the generator before operating.

NOTICE

Never modify the generator.

Never operate the generator if it 

vibrates at high levels, if engine 

speed changes greatly or if the 

engine misfires often.

Always disconnect tools or 

appliances from the generator 

before starting.

GENERAL SAFETY RULES

SAFETY

Содержание 5300 Running Watts

Страница 1: ...USER MANUAL WGen5300v Portable Generator 5300 Running Watts 6600 Peak Watts 121396Rev01...

Страница 2: ...u and others to be seriously hurt or killed Model Number Running Watts Peak Watts Fuel Tank Size G L Rated Speed RPM Ignition Type Spark plug Engine Disp cc Stroke X Bore Oil Capacity L Oil Type THD W...

Страница 3: ...ator you will need to locate the serial number WESTINGHOUSE PRODUCT REGISTRATION FORM PERSONAL INFORMATION GENERATOR INFORMATION First Name ________________________________________ Model Number ______...

Страница 4: ...oat the Neutral Ground 16 Engine Fluids and Fuel 16 Adding Gasoline to the Fuel Tank 17 Power Output and Demand 18 Breaking in the Engine 18 Starting the Generator 18 Manual Start 18 Stopping the Gene...

Страница 5: ...ch if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can c...

Страница 6: ...d area Never remove the fuel cap with the engine running Never refuel the generator while the engine is running Always turn engine off and allow the generator to cool before refueling Only fill fuel t...

Страница 7: ...Westinghouse Outdoor Power Equipment LLC 7 SAFETY SAFETY LABELS AND DECALS 5 1 1 3 3 4 4 2 4 2 6 6 ON COLD START OFF RUN WARM START 5 5503Rev01 Westinghouse Outdoor Power Equipment LLC...

Страница 8: ...8 Westinghouse Outdoor Power Equipment LLC SAFETY SAFETY LABELS AND DECALS 7 12 8 9 11 10 6 11 12 6 7 9 10 8...

Страница 9: ...y cut two sides of the carton to remove the generator WHAT COMES IN THE BOX Manual Quick Start Guide Liter Bottle of SAE 10W30 Oil 1 Spark Plug Socket Wrench 1 Wheel Assembly Wrench Wheel Kit Accessor...

Страница 10: ...ne side Make sure all engine oil and fuel are drained from the unit prior to assembling Once assembled the wheel kit is not intended for on road use The wheel kit is designed for use on this generator...

Страница 11: ...ets Oil Fill Plug Dipstick Must be removed to add and check oil Oil Drain Bolt Must be removed to drain engine oil Never Flat Wheels For easy portability Fuel Valve Controls the flow of fuel from the...

Страница 12: ...ine or the spark plug CARB Canister Required for models sold into and used in California Muffler and Spark Arrester Avoid contact until engine is cooled down Spark arrestor prevents sparks from exitin...

Страница 13: ...tlet to 30amps 20 Amp Circuit Breaker Each circuit breaker limits the current that can be delivered through the 120 Volt duplex outlets to 20amps Engine Control Switch Allows fuel to flow to engine an...

Страница 14: ...ting The generator must be grounded to prevent electrical shock due to faulty appliances High Altitude Operation Engine power is reduced the higher you operate above sea level Output will be reduced a...

Страница 15: ...pliance on the top line of the chart Then select the rated amperage of the generator on the left side of the chart Where the two meet is the size of the conductor required for the application When usi...

Страница 16: ...Attempting to start the engine can damage engine components The owner of the generator is responsible to ensure the proper oil level is maintained during the operation of the generator Failure to mai...

Страница 17: ...tor verify the following The engine is filled with engine oil See Checking Engine Oil The generator is situated in a proper location Location Selection The generator is on a dry surface Weather and Dr...

Страница 18: ...starting power demand of at least 1 2 900 W which equals 1 080 W Similarly a 1 650 W air compressor can be assumed to have a starting power demand of at least 3 5 1 650 W which equals 5 775 W To prev...

Страница 19: ...ceptacles 2 Allow the generator to run at no load to reduce and stabilize engine and alternator temperatures 3 Position the engine control switch to Figure 13 Stopping the generator NOTE If you plan t...

Страница 20: ...generator to malfunction and could result in death or serious injury NOTICE Periodic maintenance intervals vary depending on generator operating conditions Operating the generator under severe condit...

Страница 21: ...stor see Figure 14 Figure 14 Remove Screw Holding Spark Arrestor 4 If the spark arrestor screen shows signs of wear rips tears or large openings in the screen replace the spark arrestor screen NOTE On...

Страница 22: ...k see Figure 18 below Figure 18 Oil Fill Plug Dipstick 6 Check oil level When checking the engine oil remove the oil fill plug dipstick and wipe it clean Thread the oil fill plug dipstick all the way...

Страница 23: ...apply slow but firm squeezing action 6 Rinse in clean water by submerging the air filter elements in fresh water and applying a slow squeezing action CHANGING ENGINE OIL 1 Always operate or maintain...

Страница 24: ...ug boot by firmly pulling the plastic spark plug boot handle directly away from the engine see Figure 23 NOTICE Never apply any side load or move the spark plug laterally when removing the spark plug...

Страница 25: ...ush Rod 2 Feeler Gauge Area 3 Rocker Arm 4 Jam Nut 5 Adjusting Nut Table 3 Standard Valve Lash Intake Valve Exhaust Valve Valve Lash 0 0035 0 0043 in 0 09 0 11 mm 0 0043 0 0051 in 0 11 0 13 mm Bolt To...

Страница 26: ...e fumes can come in contact with an ignition source such as a 1 pilot light of a stove water heater clothes dryer or any other gas appliance or 2 spark from an electric appliance NOTICE Gasoline store...

Страница 27: ...irty plugged spark arrestor 9 Check and clean the spark arrestor 10 Stale fuel 10 Drain fuel and replace with fresh fuel 11 If trying 1 11 above does not solve the problem the cause might be the gener...

Страница 28: ...0 GENERATOR CORD 50A 120 240V 14 50P TO 14 50R 30211625C 25 GENERATOR CORD 30A 120V L14 30P TO 4X 5 20R 30211650C 50 GENERATOR CORD 30A 120V L14 30P TO 4X 5 20R 30114A GENERATOR PLUG ADAPTER 30A 120V...

Страница 29: ...74053 116 FRAME 2 531315 VIB MOUNT ISOLATOR 3 90016 NUT M6 4 90018 NUT M8 5 90011 NUT M8 6 91325 BOLT M6X12 7 95021 CARBON CANISTER AND AIR FILTER CON NECTING HOSE 8 91327 BOLT M6X12 9 520308 MUFFLER...

Страница 30: ...ESCRIPTION 1 400201 CRANKCASE 2 93509 CRANKCASE OIL SEAL 3 93520 SWING ROD OIL SEAL 4 403901 RACKING BAR 5 96804 SWINGING ROD GASKET 6 383902 RETAINING CLIP 7 91816 OIL DRAIN BOLT 8 94007 OIL DRAIN BO...

Страница 31: ...IEW PART NO NO PART DESCRIPTION 12 401601 PISTON RING ASSEMBLY 13 401501 CONNECTING ROD ASSEMBLY 14 405501 PISTON PIN 15 241301 PISTON PIN RING 16 400301 CRANKSHAFT 17 402002 CAMSHAFT ASSEMBLY 18 2409...

Страница 32: ...32 Westinghouse Outdoor Power Equipment LLC WGen5300v SCHEMATIC...

Страница 33: ...Hotline 855 944 3571 777 Manor Park Drive Columbus OH 43228 TM 2020 Westinghouse Electric Corporation 2019 Westinghouse Outdoor Power Equipment LLC All Rights Reserved 09 26 19KD WestinghouseOutdoorPo...

Отзывы: