Westinghouse 5300 Running Watts Скачать руководство пользователя страница 26

26 | Westinghouse Outdoor Power Equipment, LLC

WARNING

Before attempting to service or troubleshoot the generator, the owner or service technician must first read the owner’s 

manual and understand and follow all safety instructions. Failure to follow all instructions may result in conditions that can 

lead to voiding of the EPA certification or product warranty, serious personal injury, property damage or even death.

TROUBLESHOOTING 

PROBLEM

POTENTIAL CAUSE

SOLUTION

Engine is running, but no 

electrical output

1. Circuit breakers are tripped.

1. Reset the circuit breakers and check 

for overload condition.

2. The power cord’s plug connector is not 

fully engaged in the generator’s outlet.

2. Verify plug connector is firmly engaged 

in the generator’s outlet. If using the 

240V outlet, make sure plug connector 

is rotated 1/4 turn in the clockwise 

direction.

3. Faulty or defective power cord

3. Replace power cord.

4. Faulty or defective electrical appliance

4. Try connecting a known good 

appliance to verify the generator is 

producing electrical power.

5. If trying 1-5 above does not solve the 

problem, the cause might be the generator 

has a fault.

5. Take the generator to your nearest 

authorized service dealer.

MAINTENANCE 

STORING GENERATOR

WARNING

Never store a generator with fuel in the tank 

indoors or in a poorly ventilated area where the 

fumes can come in contact with an ignition source 

such as a: 1) pilot light of a stove, water heater, 

clothes dryer or any other gas appliance; or 2) 

spark from an electric appliance.

NOTICE

Gasoline stored for as little as 60 days can go bad, causing gum, 

varnish and corrosive buildup in fuel lines, fuel passages and the 

engine. This corrosive buildup restricts the flow of fuel, preventing 

an engine from starting after a prolonged storage period.

Proper care should be taken to prepare the generator for 

any storage.
1.  Make sure the Engine Switch is switched to 

 so the 

generator does not draw power from battery. 

2. 

Clean the generator as outlined in 

Cleaning the 

Generator

.

3.  Drain all gasoline from the fuel tank as best as 

possible.

4.  With the fuel shut off valve open, start the engine 

and allow the generator to run until all the remaining 

gasoline in the fuel lines and carburetor is consumed 

and the engine shuts off.

5.  Close the fuel shut off valve.
6.  Drain the remaining gas in the carburetor float bowl 

outlined in 

Draining Carburetor Float Bowl

.

7. 

Change the oil (see 

Changing Engine Oil

).

8.  Remove the spark plug (see 

Spark Plug Maintenance

and place about 1 tablespoon of oil in the spark plug 

opening. While placing a clean rag over the spark 

plug opening, slowly pull there coil handle to allow the 

engine to turn over several times. This will distribute 

the oil and protect the cylinder wall from corroding 

during storage.

9.  Replace the spark plug (see 

Spark Plug Maintenance

).

10.  Move the generator to a clean, dry place for storage.

Содержание 5300 Running Watts

Страница 1: ...USER MANUAL WGen5300v Portable Generator 5300 Running Watts 6600 Peak Watts 121396Rev01...

Страница 2: ...u and others to be seriously hurt or killed Model Number Running Watts Peak Watts Fuel Tank Size G L Rated Speed RPM Ignition Type Spark plug Engine Disp cc Stroke X Bore Oil Capacity L Oil Type THD W...

Страница 3: ...ator you will need to locate the serial number WESTINGHOUSE PRODUCT REGISTRATION FORM PERSONAL INFORMATION GENERATOR INFORMATION First Name ________________________________________ Model Number ______...

Страница 4: ...oat the Neutral Ground 16 Engine Fluids and Fuel 16 Adding Gasoline to the Fuel Tank 17 Power Output and Demand 18 Breaking in the Engine 18 Starting the Generator 18 Manual Start 18 Stopping the Gene...

Страница 5: ...ch if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can c...

Страница 6: ...d area Never remove the fuel cap with the engine running Never refuel the generator while the engine is running Always turn engine off and allow the generator to cool before refueling Only fill fuel t...

Страница 7: ...Westinghouse Outdoor Power Equipment LLC 7 SAFETY SAFETY LABELS AND DECALS 5 1 1 3 3 4 4 2 4 2 6 6 ON COLD START OFF RUN WARM START 5 5503Rev01 Westinghouse Outdoor Power Equipment LLC...

Страница 8: ...8 Westinghouse Outdoor Power Equipment LLC SAFETY SAFETY LABELS AND DECALS 7 12 8 9 11 10 6 11 12 6 7 9 10 8...

Страница 9: ...y cut two sides of the carton to remove the generator WHAT COMES IN THE BOX Manual Quick Start Guide Liter Bottle of SAE 10W30 Oil 1 Spark Plug Socket Wrench 1 Wheel Assembly Wrench Wheel Kit Accessor...

Страница 10: ...ne side Make sure all engine oil and fuel are drained from the unit prior to assembling Once assembled the wheel kit is not intended for on road use The wheel kit is designed for use on this generator...

Страница 11: ...ets Oil Fill Plug Dipstick Must be removed to add and check oil Oil Drain Bolt Must be removed to drain engine oil Never Flat Wheels For easy portability Fuel Valve Controls the flow of fuel from the...

Страница 12: ...ine or the spark plug CARB Canister Required for models sold into and used in California Muffler and Spark Arrester Avoid contact until engine is cooled down Spark arrestor prevents sparks from exitin...

Страница 13: ...tlet to 30amps 20 Amp Circuit Breaker Each circuit breaker limits the current that can be delivered through the 120 Volt duplex outlets to 20amps Engine Control Switch Allows fuel to flow to engine an...

Страница 14: ...ting The generator must be grounded to prevent electrical shock due to faulty appliances High Altitude Operation Engine power is reduced the higher you operate above sea level Output will be reduced a...

Страница 15: ...pliance on the top line of the chart Then select the rated amperage of the generator on the left side of the chart Where the two meet is the size of the conductor required for the application When usi...

Страница 16: ...Attempting to start the engine can damage engine components The owner of the generator is responsible to ensure the proper oil level is maintained during the operation of the generator Failure to mai...

Страница 17: ...tor verify the following The engine is filled with engine oil See Checking Engine Oil The generator is situated in a proper location Location Selection The generator is on a dry surface Weather and Dr...

Страница 18: ...starting power demand of at least 1 2 900 W which equals 1 080 W Similarly a 1 650 W air compressor can be assumed to have a starting power demand of at least 3 5 1 650 W which equals 5 775 W To prev...

Страница 19: ...ceptacles 2 Allow the generator to run at no load to reduce and stabilize engine and alternator temperatures 3 Position the engine control switch to Figure 13 Stopping the generator NOTE If you plan t...

Страница 20: ...generator to malfunction and could result in death or serious injury NOTICE Periodic maintenance intervals vary depending on generator operating conditions Operating the generator under severe condit...

Страница 21: ...stor see Figure 14 Figure 14 Remove Screw Holding Spark Arrestor 4 If the spark arrestor screen shows signs of wear rips tears or large openings in the screen replace the spark arrestor screen NOTE On...

Страница 22: ...k see Figure 18 below Figure 18 Oil Fill Plug Dipstick 6 Check oil level When checking the engine oil remove the oil fill plug dipstick and wipe it clean Thread the oil fill plug dipstick all the way...

Страница 23: ...apply slow but firm squeezing action 6 Rinse in clean water by submerging the air filter elements in fresh water and applying a slow squeezing action CHANGING ENGINE OIL 1 Always operate or maintain...

Страница 24: ...ug boot by firmly pulling the plastic spark plug boot handle directly away from the engine see Figure 23 NOTICE Never apply any side load or move the spark plug laterally when removing the spark plug...

Страница 25: ...ush Rod 2 Feeler Gauge Area 3 Rocker Arm 4 Jam Nut 5 Adjusting Nut Table 3 Standard Valve Lash Intake Valve Exhaust Valve Valve Lash 0 0035 0 0043 in 0 09 0 11 mm 0 0043 0 0051 in 0 11 0 13 mm Bolt To...

Страница 26: ...e fumes can come in contact with an ignition source such as a 1 pilot light of a stove water heater clothes dryer or any other gas appliance or 2 spark from an electric appliance NOTICE Gasoline store...

Страница 27: ...irty plugged spark arrestor 9 Check and clean the spark arrestor 10 Stale fuel 10 Drain fuel and replace with fresh fuel 11 If trying 1 11 above does not solve the problem the cause might be the gener...

Страница 28: ...0 GENERATOR CORD 50A 120 240V 14 50P TO 14 50R 30211625C 25 GENERATOR CORD 30A 120V L14 30P TO 4X 5 20R 30211650C 50 GENERATOR CORD 30A 120V L14 30P TO 4X 5 20R 30114A GENERATOR PLUG ADAPTER 30A 120V...

Страница 29: ...74053 116 FRAME 2 531315 VIB MOUNT ISOLATOR 3 90016 NUT M6 4 90018 NUT M8 5 90011 NUT M8 6 91325 BOLT M6X12 7 95021 CARBON CANISTER AND AIR FILTER CON NECTING HOSE 8 91327 BOLT M6X12 9 520308 MUFFLER...

Страница 30: ...ESCRIPTION 1 400201 CRANKCASE 2 93509 CRANKCASE OIL SEAL 3 93520 SWING ROD OIL SEAL 4 403901 RACKING BAR 5 96804 SWINGING ROD GASKET 6 383902 RETAINING CLIP 7 91816 OIL DRAIN BOLT 8 94007 OIL DRAIN BO...

Страница 31: ...IEW PART NO NO PART DESCRIPTION 12 401601 PISTON RING ASSEMBLY 13 401501 CONNECTING ROD ASSEMBLY 14 405501 PISTON PIN 15 241301 PISTON PIN RING 16 400301 CRANKSHAFT 17 402002 CAMSHAFT ASSEMBLY 18 2409...

Страница 32: ...32 Westinghouse Outdoor Power Equipment LLC WGen5300v SCHEMATIC...

Страница 33: ...Hotline 855 944 3571 777 Manor Park Drive Columbus OH 43228 TM 2020 Westinghouse Electric Corporation 2019 Westinghouse Outdoor Power Equipment LLC All Rights Reserved 09 26 19KD WestinghouseOutdoorPo...