25
Operation
Resistance Measurements
Attention! Under no circumstances conduct resistance measure-
ments on voltage carrying circuitry!
1. Connect the black measuring cable to the COM input (6)
and the red measuring cable to the V/
Ω
/
input (5).
2. Then set the rotary function switch (3) to the desired
measuring range (2000
Ω
or 200 K
Ω
).
3. Connect the measuring cables to the resistor you intend to
test.
Read the result from the display.
Please Note:
When taking measurements in the range under 200 K
Ω
it
can take several seconds before a stable value is reached.
If the measuring range is exceeded, a “1” is displayed as
overflow indicator.
Keep the measuring tips clean to ensure a good connection.
Range Resolution Accuracy
Overload
protection
2000
Ω
1
Ω
± 1.2 % of measured
value + 2 digits
200 K
Ω
100
Ω
± 1.5 % of measured
value + 2 digits
DC 250 V
AC 250 Vrms
Diode Test Function
With this function you can test diodes and other semiconductors
for continuity and blocking function.