![Westfalia 64 56 89 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/westfalia/64-56-89/64-56-89_instruction-manual_963339018.webp)
13
Operation
Accuracy
Range
Resolution
Accuracy (50 - 500 Hz)
450 V
1 V
± 1 % of Measured Value + 4 Digits
Input resistance 10 M
Ω
DC Voltage Measurements
•
Connect the black measuring cable to the COM input (7) and the red
measuring cable to the V/
Ω
input (6).
•
Then set the rotary function switch (4) to the desired measuring range
(V / 600 V).
•
Connect the measuring tips parallel to the circuitry and observe correct
polarity (Red to plus; black to minus) and read the voltage from the display.
•
Is a minus symbol appears in the display, correct the polarity.
•
Please make sure not to exceed 600 V.
Accuracy
Range
Resolution
Accuracy
600 V
1 V
± 0.8 % of Measured Value + 1 Digit
Input Resistance 9 M
Ω
Resistance Measurements
Attention! Under no circumstances conduct resistance measurements on
voltage carrying circuitry!
•
Connect the black measuring cable to the COM input (7) and the red
measuring cable to the V/
Ω
input (6).
•
Then set the rotary function switch (4) to the desired measuring range
(
Ω
/ 20K or 2M).
•
Connect the measuring cables to the resistor you intend to test.
•
Read the result from the display.