background image

Programming 

 

 

25 

Pd  Return to Factory Settings 

If it will be necessary to set the program to factory setting, proceed as follows: 
1. 

Hold the button 

FUNC

 pressed for more than 4 seconds. 

2. 

The display shows 

P1

. The unit is in the setting mode for operating 1 resp. 2 

gate openers. 

3. 

Press the button 

FUNC

 several times until the display shows 

Pd

4. 

Hold  the  button 

INC

  pressed  for  approx.  2  seconds  in  order  to  set  the 

program to factory settings. The display shows 

dF

5. 

If all adjustments are made and in order to quit the program, press the button 

FUNC

. The display shows 

– –

“. The unit enters Standby mode again. 

Содержание 18 39 13

Страница 1: ...Swing Gate Opener Artikel Nr 18 39 13 Instruction Manual...

Страница 2: ...ructions for further reference This operating instruction contains important details for handling the device Please pass it on along with the unit if it is handed over to a third party Please read all...

Страница 3: ...or Death 1 Keep Gate clear Gate may move at any time 2 Do not allow children to operate the gate or play in the gate area 3 The gate area is for vehicles only 4 Read and understand the manual 5 Pedest...

Страница 4: ...ost Pivot Bracket 2 Pieces 8 Gate Bracket 2 Pieces 9 Washer M10 mm 14 Pieces 10 Hex Bolt M10 x 200 mm 8 Pieces 11 Lock Washer M10 mm 14 Pieces 12 Hex Bolt M10 x 75 mm 4 Pieces 13 Washer M8 mm 2 Pieces...

Страница 5: ...Force for Gate Opener 1 Page 21 P6 Adjusting the Blocking Force for Gate Opener 2 Page 22 P7 Closing Time for Gate Opener 1 Page 22 P8 Closing Time for Gate Opener 2 Page 22 P9 Photocell Beam System...

Страница 6: ...se the swing gate opener with a damaged swing gate system Do not use the swing gate opener unless repair work or alignment is carried out properly Disable the existing swing gate locks in order to avo...

Страница 7: ...ntrol directly on your body For your safety when using the remote control keep it away from your body and in direction to the gate Before undertaking any maintenance on the swing gate opener unplug fr...

Страница 8: ...should not be damaged or has signs of wear It must be possible to open and close the gate by hand without any problems The mechanical gate lock must be dismounted resp disengaged The control box may o...

Страница 9: ...Mounting Possibilities 5 Warnschild Warning Sign Opener 2 Property 2 Property 2 Opener 1 Warning Sign Warning Sign Opener 2 Opener 1 Property 2...

Страница 10: ...NCY STOP Main Switch In case of questions contact a professional For correctly programming the gate openers it is essential that gate opener 1 is mounted at the right side of the gate and gate opener...

Страница 11: ...t is set in cement in order to ensure stability When mounting on stone or concrete posts use dowels that cannot slacken Preferably use compound anchors better than standard steel and PVC expansion dow...

Страница 12: ...ten 3 Mount the gate opener 1 with the already assembled bracket assy post pivot bracket and post bracket and use the clevis pin 20 and the hairpin clip 19 in order to lock the opener Make sure the ga...

Страница 13: ...footpaths or roads while operating Please mind the table on the next page in order to determine the correct position of the mounting material resp the gate opener The distances A B must not exceed 42...

Страница 14: ...Reference Table 10...

Страница 15: ...press down while turning the key counter clockwise By doing this the gate opener will be unlocked Now the moving rod can be extended The moving rod should always be lubricated sufficiently Make sure...

Страница 16: ...correct position of the gate opener and the bracket assy Please also observe the drawings on the next page Make sure the min distance between gate and gate opener is 2 5 cm This distance must be maint...

Страница 17: ...m Min 2 5 cm Gate is in CLOSED Position Moving Rod is extended Danger Area Pinch Area Make sure the gate opener and the bracket do not hit each other Danger Area Pinch Area Gate is in OPEN Position Mo...

Страница 18: ...drill holes with 10 mm diameter into the gate 3 Tighten all screws and nuts Protruding bolt ends 10 should be cut with the hacksaw Cover the gate opener while drilling Please note that dust and swarf...

Страница 19: ...dy Metal Tube 8 If the braces of the gate are thin the braces can be reinforced with sturdy metal tubes By doing this the gate bracket 8 can be mounted securely on the braces A wooden or metal plate c...

Страница 20: ...gate opener from below into the control box Pull enough cable and tighten the lock nuts of the strain relief The cables are labelled with small flags Please observe the flags and arrange them correctl...

Страница 21: ...Wiring Diagram 17 Connecting the control box to power mains Neutral to contact 3 Phase to contact 1 The numbers for the resp terminals are shown on the transparent cover...

Страница 22: ...Opener 1 Opener 2 Limit Switch Limit Switch Limit Switch Limit Switch Motor 1 Motor 2 Before operating the gate opener for the first time thoroughly check all mounting material and make sure the gate...

Страница 23: ...ontrol box is connected to power mains the display starts flashing and shows Now the unit is in Standby 2 Hold the button FUNC pressed for more than 4 seconds The display shows P1 The unit is in setti...

Страница 24: ...delay and close first 1 Press the buttons INC or DEC 01 indicates the gate opener 1 will open and close as Master gate 10 indicates that gate opener 2 will open and close as Master gate 2 Press the b...

Страница 25: ...f the obstruction sensitively is adjusted properly the gate will reverse automatically as soon as the gate comes into contact with an obstruction Based on the length and the weight of the gate it may...

Страница 26: ...ible Each time you press the button INC the value will increase and when pressing the button DEC the value will decrease Hold the buttons INC or DEC pressed in order to speed up the value 2 Press the...

Страница 27: ...now in the mode Soft Start Pb Soft Start Soft Start function means that the gate will be opened and closed softly and not fitfully 1 Press the button INC or DEC in order to adjust soft start function...

Страница 28: ...he Total Run Time is 23 seconds the Fast Running Period has to be adjusted to 15 seconds in order to meet the Soft Stop Period of 5 seconds Adjust in the Menu Pb 3 seconds Adjust in the Menu PC 15 sec...

Страница 29: ...ows P1 The unit is in the setting mode for operating 1 resp 2 gate openers 3 Press the button FUNC several times until the display shows Pd 4 Hold the button INC pressed for approx 2 seconds in order...

Страница 30: ...s repeat the above mentioned steps Up to 6 remote controls can be programmed If you lose one remote control for safety reason please program all other remote controls to have a new code Erase all Remo...

Страница 31: ...l reverse direction and stop at the adjusted position Adjusting the Limit Switch The gate is opened or closed with the moving rod As soon as the limit switch position is reached the gate opener switch...

Страница 32: ...sed by hand Insert the triangular key into the opening and turn the key counter clockwise The motor is now unlocked Using the Remote Control from the Car The gate is closed 1 Hold the remote control c...

Страница 33: ...te As soon as the gate comes in contact with an obstruction the gate reverses and stops in the adjusted position Maintenance and Cleaning Lubricate the moving rod from time to time in order to ensure...

Страница 34: ...ower Cable 150 900 cm Speed mm sec 16 load dependent Max Moving Rod Travel 385 mm Operating Temperature 22 C 50 C Protection Class IP44 Short Time Operation for Swing Gate Opener KB Time 4 Minutes Dim...

Страница 35: ...ng existing or separately purchased special accessory please note the included connection diagram Make sure the special accessory is suitable for the gate opener The special accessories shown in the c...

Страница 36: ...Connection Diagram for Accessory 32 reserved...

Страница 37: ...oduct Swing Gate Opener Article No 18 39 13 is according to the basic requirements which are defined in the European Directives 1999 5EC R TTE Directive 2011 65 EU Restriction of the Use of certain ha...

Страница 38: ...nternet www westfalia net Kundenbetreuung Customer Services is Werter Kunde bitte helfen Sie mit Abfall zu vermeiden Sollten Sie sich einmal von diesem Artikel trennen wollen so bedenken Sie bitte das...

Отзывы: