Document: 1856en01.doc
QWTIME III MASTER CLOCK
Author: PM
Date: 2011-02-25
User Manual
Page: 20 o f 23
WESTERSTRAND URFABRIK AB
P.O. Box 133
Tel. +46 506 48000
Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA
Fax. +46 506 48051
E-mail:
Setup sync. source
Below is a description of the different configuration parameters available in the setup menu for
sync. source
.
Please remark that if default settings are used no configuration is needed.
Type of synchronisation
State type of external synchronisation. The following time sources can be selected:
--------
No external synchronisation.
DCF77
Radio synchronisation DCF77.
GPS
Radio synchronisation GPS.
RDS
Radio synchronisation RDS.
MSF
Radio synchronisation MSF/RUGBY.
1/1M SYNC
Polarised 1/1-minute impulse, sync.
1/1M SLAVE
Polarised 1/1-minute impulse, slave.
1/2M SYNC
Polarised 1/2-minute impulse, sync.
1/2M SLAVE
Polarised 1/2-minute impulse, slave.
TC
Time code type hard wired DCF.
TC-POL
Polväxlande tidkod typ ledningsbunden DCF-kod.
FMSF
Finnish FM time signal.
NTP CLIENT
The Master Clock is NTP client*
AFNOR
Time code according to AFNOR NFS-87500 (IRIG-B with date)**
*Only applicable if the Master Clock is equipped with option Ethernet.
**Only applicable if the Master Clock is equipped with option IRIG-B.
Alarm limit
The configuration parameter
Alarm limit
specifies the time delay before the radio alarm is activated. Default
setting is that the radio alarm is inactivated, AL.LIMIT --h--m.
DCF77
AL. LIMIT 12h00m
Type of synchronisation
Alarm limit