The Temperature sensor is not included. It is an option.

 

The programming of the time and temperature display is made by buttons at the computer board or via 
remote control. 
The digital clock can operate stand-alone with a built in quartz crystal as time reference, as a slave 
clock to a master clock transmitting 24 V polarised 1/1 minute impulses or synchronised by TC, DCF 
or GPS. 
If the DLS-function is set , the clock is changing summer and winter time, the last Sunday in March 
and the last Sunday in October automatically. 
The clock has adjustable light intensity. 
If power failure occurs the display is turned off. The internal clock continues to keep the correct time 
for 48 hours. After the power failure the display is turned on and correct time is shown.  
 
 
 

Installation 

 

 

Mount the clock by means of the mounting brackets. Both wall and roof mounting is possible by 
rotating the brackets. 

 

To open the clock, slide the front glass by loosening the aluminium profile on the short side of the 
clock. Unscrew 2 screws and open the service plate. 

 

Connect the synchronisation source if present (radio, impulse etc). See the connection diagrams, 
page 5. 
See also the configuration instructions for setting of synchronisation (page. 6 and 8.) 

 

Connect the mains, 230VAC 50Hz . Installation fuse max 10A. 
The socket outlet shall be installed near the clock and shall be easily accessible. 
When the clock is installed permanently, a readily accessible disconnect device (2-polar, 3 mm 
contact gap) shall be incorporated in the fixed wiring. 

 

Set correct time and date according to the programming instructions on page 10. 

 
 

 
 
 
 
 
 
 
 

 

 
 
 

Содержание 190100 Series

Страница 1: ...10 doc Auth TAn Date 2016 11 07 Page 1 of 16 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Manual Westerstra...

Страница 2: ...in 1 25 seconds intervals Consists of 7 segments LED digits in dimensions 150 190 250 300 and 450 mm The time and temperature display could be single or double sided with or without second One side c...

Страница 3: ...isplay is turned off The internal clock continues to keep the correct time for 48 hours After the power failure the display is turned on and correct time is shown Installation Mount the clock by means...

Страница 4: ...Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Connection Connection synchronisation TC and MIN imp is connected at IMP and IMP V IMP...

Страница 5: ...07 Page 5 of 16 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Strapping TC MIN impulse computer board defaul...

Страница 6: ...as follows Dip 1 OFF Display format is HH MM ON Display format is HH MM SS Dip 2 OFF always OFF Dip 3 OFF TC Min impulse synchronisation default ON DCF GPS synchronisation Dip 4 OFF TC Min impulse or...

Страница 7: ...T T in slave mode InSL see programming page 10 Set time and wait for next minute impulse It is now working in slave mode TC Set the straps according to the strapping schema page 6 Connect the TC wire...

Страница 8: ...of 16 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Connection temperature sensor option Temperature sensor...

Страница 9: ...at the computer board Remote control R Return Enter the base mode display time F Function Next function Accept displayed value P Program Enter the displayed function Increase displayed value Manual p...

Страница 10: ...isplay shows Setting light intensity The light intensity for the digits has one minimum and one maximum level The setting levels 1 50 are set in function disp An automatic dimmer function regulates th...

Страница 11: ...se Push R for entering base mode or push F for next function Setting synchronisation Synchronisation for this model is minute impulse TC DCF GPS or stand alone Push F until display shows Push P for d...

Страница 12: ...hows Alternating time for display temperature is 0 Push P for desired alternating temperature 0 25 Accept with F Display shows Alternating time for display date is 4 seconds Push P for desired alterna...

Страница 13: ...ction the DLS can be activated Push F until display shows Push P Display shows Or Push P for DLS or not Push R for entering base mode or push F for next function Setting12 24 h format With this functi...

Страница 14: ...e range temperature sensor 30 C 60 C Accuracy temperature sensor 1 C Temperature measurement Once per minute Specific for 190100 xx Type Single sided without second Connection current max 2A Size of d...

Страница 15: ...HH MM SS 190mm 190mm 150mm Dimension WxHxD 1070x270x92mm 190131 xx Type Double sided with second Connection current max 2A Size of digits HH MM SS 190mm 190mm 150mm Dimension WxHxD 1070x270x130mm 190...

Страница 16: ...161 xx Type Double sided without second Connection current max 2 5A Size of digits HH MM 300mm 300mm Dimension WxHxD 1000x380x130mm 190170 xx Type Single sided with second Connection current max 2 5A...

Отзывы: