Leonardo
System
1kW/1500/24
S
Manuale
Tecnico
Leonardo
System
1kW/1500/24
S
Technical
Manual
Rev.
5.0
02
‐
02
‐
2015
This
document
is
the
property
of
WESTERN
CO.
Srl
‐
All
rights
are
reserved
‐
Reproduction
and
use
of
information
contained
within
this
document
is
forbidden
without
the
written
consent
of
WESTERN
CO.
Srl
8
CONNECTION
DIAGRAM
Pic. 9 Connection Diagram
INSTALLATION
AND
WIRING
1.
Leonardo
System
1kW/1500/24
S
must
be
installed
in
a
dry
and
well
‐
ventilated
area,
fixed
on
a
non
‐
flammable
surface
and
placed
on
a
clear
space
of
at
least
10
cm
around
the
appliance/device
for
cooling.
2.
Mount
on
the
wall
the
support
bracket
(included)
through
the
included
plugs
and
screws.
Hook
‐
up
the
inverter
through
the
hook
‐
shaped
plate
located
on
the
top
of
the
device.
Fasten
the
inverter
on
the
wall
using
the
holes
located
at
the
bottom
of
the
device.
As
in
picture
10.
PV
FIELD
2
MPPT
independent
inputs
Max
Power:
1
kWp
Max
Power
for
each
input:
500
W
2
strings
of
2
60
‐
cell
PV
modules
(i.e.
250W
power)
DC/AC
INVERTER
Continuous
power
1500
VA
overcharge
threshold
1300W
AC
input
24
Vdc
battery
BATTERY
PACK
‐
System
voltage
24Vdc
‐
Recommended
Capacity
500Wp
PV
plant:
100Ah
‐
2,4kWh
‐
Recommended
Capacity
1kWp
PV
plant:
150Ah
‐
3,6kWh
MAXIMUM
SELF
‐
CONSUMPTION
FREE
CONTACT
‐
free
contact
COM
‐
NC
‐
NO
‐
4A
@
230Vac
‐
1A
@
60Vdc
‐
i.e.
Boiler
with
heat
pump
OPTIONAL
DATA
LOGGER
‐
produced
energy
‐
delivered
energy
‐
energy
independence
rate