Lit. No. 78532, Rev. 02
28
March 15, 2019
4. Remove the drain plug.
5. Completely drain the reservoir and reinstall the
drain plug.
6. Fill the reservoir to 1-1/2" to 2" from the top
with high-performance hydraulic
fl
uid rated to
–40°F (–40°C), or other
fl
uid conforming to
Military Speci
fi
cation MIL-H-5606 A, such as
Mobil Aero HFA or Shell AeroShell
®
Fluid 4.
7. Reinstall
the
fi
ll plug.
MAINTENANCE
HYDRAULIC SYSTEM
Annual Fluid Change
1. Perform this operation with the snowplow attached
to the vehicle. Park the vehicle on a hard, level
surface.
2. Lower the blade to the ground. Turn the control
OFF.
3. Remove
the
fi
ll plug.
NOTE: Remove
fi
ll plug slowly to relieve any
pressure in reservoir.
CAUTION
Change the
fl
uid at the beginning of each
plowing season. Failure to do this could
result in condensation buildup during the
non-plowing season.
CAUTION
Do not mix different types of hydraulic
fl
uid.
Some
fl
uids are not compatible and may
cause performance problems and product
damage.
AeroShell
®
is a registered (
®
) trademark of Shell Oil Company.
Breather/Fill Plug
Reservoir
Drain Plug