A.3.
SC1 Serial Card Interface
(DB-9 Male; AT PC Style)
Pin
Signal
I/O
1
DCD (Data Carrier Detect)
In
2
RXD (Receive Data)
In
3
TXD (Transmit Data)
Out
4
DTR (Data Terminal Ready)
Out
5
Signal Ground
---
6
DSR (Data Set Ready)
In
7
RTS (Ready to Send)
Out
8
CTS (Clear to Send)
In
9
Not Connected
---
A.4.
Alarm Wiring
The Alarm Port located on the unit’s back panel is designed for
connection to a user-supplied alarm device. When a Toll Fraud
alarm is generated, the PollCat III will activate the Alarm Port.
Figure A.4 and the table below describe the Alarm Port interface.
Pin
Signal
1
Do Not Connect
2
Not Connected
3
Signal Ground
4
Signal Ground
5
Do Not Connect
6
- Alarm Signal (open collector output)
Apx-3
Appendices
Figure A.4: Alarm Port Interface