Read Buffer
(
/R
)
Reads data from the buffer for a specified port. After reading
data from the buffer, the unit will wait for the Resident
Disconnect Sequence or timeout period, and then return to the
"MDS>" prompt. To terminate the Read Buffer command before
it is complete, issue the Resident Disconnect Sequence
(Default =
[Enter]
+++
[Enter]
).
When the /R command is issued from a port with "All"
(Administrator) command capability, the MDS can also be
instructed to read and then clear the buffer by including the /C
option in the command line.
Command Availability:
All (Administrator) / Basic (User)
Command Format:
/R[/C] <n>
[Enter]
Where:
/C
(Optional) Instructs the MDS to clear the buffer after
reading. Note that the /C option can only be issued by a
port with "All" command capability.
n
Is the number or name of the port buffer to be read.
Command Response:
MDS releases data from the buffer. If the
command line includes the /C option, the port buffer will also be
cleared.
Examples:
To Read data from the buffer for Port 3, access the Command
Mode from an Any-to-Any Mode Port and type the following:
/R 3
[Enter]
To Read
and
Clear data from the buffer for Port 3, access the
Command Mode from an Any-to-Any Mode Port with access to
All MDS commands and type the following:
/R/C 3
[Enter]
To Read data from the buffer for a port named DEVICE1, go to
an Any-to-Any Mode Port and type the following:
/R DEVICE1
[Enter]