4.
Hardware Installation
This section describes the procedures for installing the MDS and
connecting devices to the unit.
4.1.
Configure Setup Switches
When the MDS is shipped from the factory, the Setup Switches
are configured for 9600 baud, 8 Bits-No Parity, DTR
handshaking, verbose command response, and no echo (all
switches down). These switch settings are compatible with most
applications. If the default settings are
not
compatible with your
application, change the switch settings as described in the
following subsections.
Setup Switches should be configured to match the
communication parameters used by the device attached to Port 1.
This allows access to the MDS if the unit is initialized to default
parameters.
Note:
Communication parameters (baud rate, parity, etc.)
can also be individually selected for each MDS port
by accessing the Command Mode and invoking the /P
command as described in Section 5.3.4. However, if
the MDS is initialized, parameters will return to the
settings specified by the current Set-Up Switch
configuration.
4-1
Содержание MDS-16
Страница 20: ...4 6 MDS Series User s Guide...
Страница 38: ...6 12 MDS Series User s Guide...