3-1
3. Quick Start
This Quick Start Guide describes a simplified installation procedure for the
IPS-800-D20, IPS-800E-D20, IPS-1600-D20 or IPS-1600E-D20 hardware,
which will allow you to communicate with the unit in order to demonstrate
basic features and check for proper operation.
Note that this Quick Start Guide does not provide a detailed description of unit
configuration or discuss advanced operating features. For more information,
please refer to the Installation, Configuration and Operation sections in this
User's Guide.
3.1. Hardware Installation
3.1.1.
Apply Power to the IPS
Refer to power rating nameplate on the IPS back panel, and then connect the
unit to an appropriate power source. Note that the IPS features two separate
AC inputs and two separate power busses; connect the power cables (supplied
with the unit) to the unit's Circuit "A" and Circuit "B" Power Inlets, install
the cable keepers, then connect the cables to an appropriate power source.
Refer to the table below for information concerning power requirements and
maximum loads.
Model
Number
Total
Outlets
Input
Voltage
Max. Load
per Outlet
Max. Load
per Bus
Max. Load
per Unit
IPS-800-D20
8
100 to
120 VAC
15 Amps
20 Amps
40 Amps
IPS-800E-D20
8
100 to
240 VAC
15 Amps
20 Amps
40 Amps
IPS-1600-D20
16
100 to
120 VAC
15 Amps
20 Amps
40 Amps
IPS-1600E-D20
16
100 to
240 VAC
15 Amps
20 Amps
40 Amps
Set the Main Power Switch in the ON position; the ON LED should light, and
the RDY LED should begin to flash.