11. 

EQUIPMENT OPERATION 

 
11.1.  Procedural Frequency 

 
11.1.1.  This SOP should be followed every time the UVC BODYLight is used. 

 

11.2.  Safe Equipment Handling

 

 

11.2.1.  For extended life and efficacy of the UVC BODYLight always avoid rough 

usage and keep the Light clean and free of material splatter, overspray, 
and debris during usage.

 

11.2.2.  It is recommended to always operate the UVC BODYLight with the Bristle 

Cone in position for protective operation to all personnel and to 
appropriately gauge effective kill distance.

 

11.2.3.  Always move or carry the UVC BODYLight by the body, affixed strap, or 

handle 

– Never pull by a connected power cord.

 

11.2.4.  Do not impact the Lens with hard, sharp or heavy objects, which can 

cause the lens to scratch, chip, crack, or shatter.

 

11.2.5.  Avoid setting the UVC BODYLight FACE DOWN, especially on abrasive 

surfaces, which might result in chipping, scratching, abrading, or cracking 
of the Lens.

 

11.2.6.  Do not operate the UVC BODYLight without Bumpers.

 

11.2.7.  Do not severely bend a connected cord at any point as this may cause 

internal conductors to break and system failure.

 

 

11.3.  Charging the BODYLight Battery Pack 

 

11.3.1.  Obtain the BODYLight Battery Charger and plug it into a compliant VAC 

outlet in an Ordinary Location. 
 

11.3.1.1. 

WARNING - The charger is not explosion proof rated and 
must remain outside the hazardous location when charging 
the batteries.

 

 

11.3.2.  Obtain the BODYLight Battery Pack and screw it into the receiving hub 

on the Battery Charger until a firm contact is made and allow the Pack to 
fully charge. 
 

11.3.2.1.  Note: The Hub is fitted with a Battery Pack charge indicator ring 

that will glow 

 when the Battery Pack is in a charge cycle 

and 

 when the Battery Pack is fully charged. 

11.3.2.2.  A full charge cycle takes approximately 2.5 hours. 
11.3.2.3.  Once the Battery Pack is fully charged, the Battery Charger will 

enter into a standby mode until an additional charge is required. 

Содержание WT-GERM KILLER BODYLight 8910UVC

Страница 1: ...8910UVC BODYLight Operation SOP Number Effective Date Page WT SOP 01007 05 10July2020 1 of 17 Supersedes Scheduled Review Distribution ID WT SOP 01007 04 Biennial NA 1 PURPOSE AND OBJECTIVE The purpose of this Standard Operating Procedure is to delineate the operation of the WT GERM KILLER 8910UVC BODYLight ...

Страница 2: ...ibility of any user of the UVC BODYLight to understand and follow this SOP 4 2 It is the responsibility of any user of the UVC BODYLight to understand and comply with all procedures practices and safety protocols as outlined in this SOP 4 3 It is the responsibility of management to ensure all users are trained in the safe use of the UVC BODYLight prior to operation 5 DEFINITIONS 5 1 ATM Authorizat...

Страница 3: ...tort the molecule and prevent proper functionality 7 5 The efficacy of UVC radiation is well documented in the literature as a means to inhibit microbial viability and inactivation of COVID 19 See References Section 14 7 5 1 Recent studies indicate that an irradiance dosage of 3 6mW cm2 of UVC 260 285nm on contact surfaces is sufficient to inactivate or kill the SARS CoV 2 virus 8 PRODUCT DESCRIPT...

Страница 4: ... of 1 second germicidal inactivation of the COVID 19 virus and to provide shielding of scattered or reflected UVC radiation 8 6 The UVC BODYLight light head may be cord connected to a Battery Pack Manifold for extended power or to a Power Box which will provide continuous power if required These connections can be made within the hazardous classified area 8 7 The UVC BODYLight is thermally monitor...

Страница 5: ...idal ultraviolet rays may break down plastic rubber or other non metallic materials can fade colors and can be damaging to plant life Shield all plastic rubber or other non metallic parts plant life etc which may be exposed to direct or reflected germicidal ultraviolet rays 9 1 3 Personal Protective Equipment 9 1 3 1 Ensure all required and compliant personal protective equipment is worn to preven...

Страница 6: ...with Western Technology BODYLight Replace with Western Technology Battery Canister Only Do Not Disassemble Crush or Modify Do Not Short Circuit Do Not Heat Above 100ºC 212ºF or Dispose of in Fire 9 2 3 8910 Battery Charger WARNING This unit is Factory Sealed Do Not Open Risk of Explosion Recharge the Batteries Outside of the Hazardous Location To Reduce the Risk of Ignition of Hazardous Atmosphere...

Страница 7: ...up E F G locations Zone 1 2 and Zone 20 21 22 10 2 2 Identification 4INR19 66 10 2 3 Output Power 14 4VDC 3 4Ah 10 2 4 Temp Ambient 20º to 40ºC Temp Rating T5 10 2 5 Certified to UN 38 3 10 2 6 Conforms to UL Std 62133 10 2 7 Certified to CSA Std E62133 10 2 8 Suitable for Wet Location Use Type 6P 10 3 Battery Charger ATM BodyLight Lithium Ion Class 2 Battery Charger 10 3 1 Ordinary Location Class...

Страница 8: ...tting the UVC BODYLight FACE DOWN especially on abrasive surfaces which might result in chipping scratching abrading or cracking of the Lens 11 2 6 Do not operate the UVC BODYLight without Bumpers 11 2 7 Do not severely bend a connected cord at any point as this may cause internal conductors to break and system failure 11 3 Charging the BODYLight Battery Pack 11 3 1 Obtain the BODYLight Battery Ch...

Страница 9: ...le Cone into the groove 11 5 Operation of the UVC BODYLight 11 5 1 Put on approved PPE for potential UVC radiation exposure 11 5 2 Attaching the Power Source to the Light Head 11 5 2 1 Firmly screw on the power source Battery Pack corded Battery Pack Manifold or corded Power Box to the UVC BODYLight Light Head 11 5 2 1 1 Ensure that a fully charged Battery Pack is used if applicable 11 5 2 2 Note ...

Страница 10: ...essing and releasing the Right Button 11 5 3 6 UVC Activation Deactivation Code Mode Special Order Only 11 5 3 6 1 1 If the UVC BODYLight was provided with a UVC Lock Out Code a UVC activation code must first be entered into the system to unlock the UVC function 11 5 3 6 1 2 To enter into the UVC Code Entry Mode depress and hold both the Left On and Right Off buttons simultaneously for about 2 sec...

Страница 11: ... the BODYLight has entered into the UVC Code Entry Mode 11 5 3 6 1 8 Enter the code assigned to your organization to deactivate the UVC mode which consists of a series of button depressions 11 5 3 6 1 9 Once deactivated the UVC BODYLight will immediately enter into Battery Charge Indicator mode 11 5 4 Germicidal UVC Illumination 11 5 4 1 Turn ON the Germicidal UVC and Visible Light by depressing a...

Страница 12: ... of the effective kill zone 11 5 5 1 1 WARNING Be aware of your surroundings Do not expose individuals to UVC radiation 11 5 5 2 When operating the UVC BODYLight bring the Bristles in contact with the surface to ensure effective radiant kill energy and protective shielding from scattered or stray light 11 5 5 2 1 The zone of UVC light emission within the Bristle Cone provides 2mW cm2 radiant energ...

Страница 13: ... the BODYLight due to elevated operating temperature Upon 20 F drop in temperature the BODYLight will reset and can now be switched on 10 5 6 7 Repeating LED Blinks UVC LED emission power is noncompliant to output specifications BODYLight will not switch on Contact Western Technology for replacement of UVC LED board 10 5 6 8 None BODYLight requires power Connect the BODYLight head to a charged bat...

Страница 14: ...ed or broken 12 2 4 1 Ensure that the Gasket is in place around the base of the threads of the Connector on the Battery Canister Cord Connected Battery Pack Manifold and Cord Connected Power Box 12 2 4 1 1 This Gasket is required to be present and functional for Explosion Proof certification and usage in Hazardous Classified Locations 12 2 5 The Bumpers are in good condition and capable of protect...

Страница 15: ...CT ASSISTANCE 13 1 BODYLight Battery Pack Replacement 13 1 1 In general a Battery Pack will remain operational for approximately 500 charge cycles 13 1 2 Should a Battery Pack no longer charge or a replacement is required contact Western Technology Customer Service 13 2 BODYLight Battery Pack Disposal 13 2 1 The Battery Canister contains Li Ion batteries which are classified as hazardous waste and...

Страница 16: ...th synergy 2017 February 1 109 207 216 14 6 Chevrefils G Caron E Wright H Sakamoto G UV Dose Required to Achieve Incremental Log Inactivation of Bacteria Protozoa and Viruses 2006 March 14 7 Buonanno M Welch D Shuryak I Brenner D Far UVC light efficiently and safely inactivates airborne human coronaviruses Research Square In Review Version 1 2020 April 27 14 8 Beck SE Rodriguez RA Hawkins MA Hargy...

Страница 17: ...n No Effective Date Comments 00 20May2020 New 01 10Jun2020 Addition of UVC Activation Table Codes 02 12Jun2020 Inclusion of Section 10 5 3 6 UVC Activation Deactivation Code Mode 03 18Jun2020 Inclusion of Section 7 Theory and Section 8 Product Description 04 23Jun2020 Bristle Cone maintenance added 05 10July2020 Current references added to address COVID 19 inactivation on contact surfaces ...

Отзывы: