background image

GS03F084CA

830 Wilson St., Eugene, OR 97402 USA

541.344.7267 1.800.971.7201 [email protected] www.WesternShelter.com

Western Shelter is ISO 9001 Certified

HEPA AIR FILTRATION SYSTEM

GK-OA2000 AIR FILTRATION

PRODUCT SPECIFICATIONS:

Dimensions (LxWxH) 26”x20”x46”

Operating Speeds Variable Speed Controller

Filtration Stages 3-4

99.99% HEPA Filter, Medical Grade Standard

Cabinetry Aluminum, Closed End Rivet

Silicon Sealed Seams before Riveting Yes

Push Handle One

Casters 3” Swivel

Motor Horse Power 1 hp

Circuit Requirements (Volts/Hz) 115 VAC/60 Hz

Maximum Operating Amps 12.5 Amps

Thermal Overload Protection Yes

Pressure Gage 0-3” W.C.

Included Accessories:

Duct Boot 10”

Air duct 10”

PARTS:

Shelter HEPA Filtration System

Flexible Duct Boot 10” diameter

OdorGuard 600—Carbon filter pad, Size 24” x 16” x 2” (Mesh or Pleated)

OdorGuard 750 Plus—Carbon/Alumina/Potassium permanganate 

filter pad, size 24” x 16” x 2”

OPTIONAL ACCESSORIES:

Содержание GK-OA2000

Страница 1: ... Filtration System purifies airborn contaminants which could be biological chemical or particulates Creates small negative pressure in shelters providing isolation between operating room and the outside environment All the air pulled from the shelter is purified through 99 99 HEPA and by high intensity UVGI light before it is exhausted into the general area Carbon filters can also be added to a ma...

Страница 2: ...e Standard Cabinetry Aluminum Closed End Rivet Silicon Sealed Seams before Riveting Yes Push Handle One Casters 3 Swivel Motor Horse Power 1 hp Circuit Requirements Volts Hz 115 VAC 60 Hz Maximum Operating Amps 12 5 Amps Thermal Overload Protection Yes Pressure Gage 0 3 W C Included Accessories Duct Boot 10 Air duct 10 PARTS Shelter HEPA Filtration System Flexible Duct Boot 10 diameter OdorGuard 6...

Страница 3: ...pressure in the hallway The vinyl walls of the shelter will be bowed in indicating negative pressure As the doors to the hallway or the operating room open the pressure will temporarily change and return to negative when the doors close The higher the speed contamination of the area and electrical overload of the motor Operating UV Germicidal Lights UVGI lights is sterilized and the bio contaminan...

Страница 4: ... 344 7267 1 800 971 7201 sales westernshelter com www WesternShelter com Western Shelter is ISO 9001 Certified HEPA AIR FILTRATION SYSTEM Exhaust air duct Place on top of unit w exhaust opening facing shelter wall Attach duct with provided set screws ...

Страница 5: ... speed at any time by toggle switch being moved between SPEED CONTROL and HIGH The toggle switch overrides the SPEED CONTROLLER knob setting and runs the blower at its highest speed This is also used as a quick check of HEPA Maintenance Mechanical and Electrical place The UVGI lights should last over 15 000 hours of operation There are two high intensity lights UVGI lights and two ballasts The LED...

Страница 6: ...t in such case or if Western Shelter Systems elects not to repair or replace the purchaser will be entitled only to a refund of monies paid to Western Shelter Systems for the shelter does not apply to damages caused by any force of nature to accidental or deliberate damage of the product or to use of the product that does not conform with the product instructions Exclusion Of All Other Warranties ...

Отзывы: