is  connected  to  two  0.150  ampere  lamps 

mounted inside  the  meter  case. 

The  output  level  (deflection  to  the  0  vu  or 

100  mark)  to  be  indicated  by  the  meter  is 

set  by  means  of  the  volume  indicator  range 
switch  to  correspond  to  levels  at  the  outgo­

ing  line  of  +4,  +6,  +8,  +10.  +12  and  +14 
vu.  In most cases  +8 vu  is  a  satisfactory lev­

el  to  feed  a  line.  This  range  switch  has  an 

OFF  position,  and  a  PLATE  and  FILA­

MENT  position  for  checking  plate  and  fila­
ment  batteries.  For  the  purpose  of  checking 
battery voltages,  the 0  vu  or  100 mark on  the 
scale  indicates  the  minimum  operating  volt­
age.  Checking  may  be  done  during  program 

without  interfering  with  the  operation  of  the 
amplifier. 

Monitorin9 

Two  monitoring  jacks  are  provided  on  the 

right  hand  end  of  the  front  panel  of  the  am­
plifier.  These  jacks  are  connected  in  parallel 

and  are  intended  to  provide  monitoring  fa­

cilities  for  the  operator  and  a  second person. 
They are bridged across the output of the line 
pad  in  use.  As  shown  in  the  schematic  dia­
gram,  Figure  3,  an  isolation  resistor  is  in­
cluded  in  the  monitoring  jack  circuit  to 

isolate  the  program  channel  from  an  acci­
dental  short  circuit.  The  jacks  accommodate 

Western  Electric  Type  47  or  similar  type 

plugs. 

When  loudspeaker  monitoring  is  desired, 

or  when  sound  reinforcement  is  required,  a 

Western  Electric  124E  or  142A  Amplifier, 

or  equivalent,  may  be  used.  These  amplifiers 

have  a  high  impedance  input  which  can  be 
bridged  directly  across  the  line  or  plugged 

into  one  of  the  headset  monitoring  jacks  of 
the  22E  Amplifier. 

A  47  Type  Plug  and  a  cord  such  as  the 

630  Type  are  recommended  for  making  con­
nections  between  the  22E  Amplifier  and  the 
monitoring  amplifier. 

ES-610199  Power  Unit 

For  a-c  operation,  the  ES-610199  Power 

Unit  provides  all  necessary  power  for  fila­

ment.<\  and  plates.  One  type  80  rectifier  tube 

serves  as  the  plate  supply  rectifier.  The  unit 
contains  a  receptacle  for  the  battery  unit 
cord  and  plug,  and  two  switches  so  that  the 

filament  and  plate  supplies  may  be  obtained 
from  either  batteries  or  the  a-c  supply.  All 
power  connections  to  the  Amplifier-Control 
Unit  are  made  with  a  single  6-foot,  heavy 

duty,  five-conductor cable.  A  plug  cap  is  f.ur­

nished  in  the  power  unit  socket  for  the  pur­

pose  of  connecting a length  of  rubber-covered 
cordage  from  an  a-c  outlet.  The  cordage  and 
the  male  cap  are  not  furnished  as  a  part  of 
the  unit. 

B-147071  Set  of  Ac:c:essories  for  Battery 

Operation 

The  B-147071  set  of  accessories  is  a  kit 

containing  all  the  parts  necessary  to  adapt 
the  lower  compartment  of  the  battery  carry­
ing  case  to  accommodate  a  complete  set  of 

batteries  for  battery  operation.  A  length  of 

cable,  connecting  wires,  hardware  and  com­

plete  instructions  for  installing  the  batteries 
are  included  in  the  kit.  Batteries  are  not fur­
nished,  and  must  be  ordered  separately  if 

required.  A  list  of  batteries  required  for  op­

eration  is  given  in  the  section  "Acce:<sories 

Required". 

INSTALLATION 

In  ordering,  it  is  necessary  to  specify 

whether  the  22E Speech  Input  Equipment is 
intended  for  a-c  or  for  battery  operation,  or 
for  both,  and  which  type  volume  indicator 
meter  is  desired. 

Equipment  Furnished 
For  AC  Operation 

When  a-c  operation  is  specified,  the  equip­

ment  furnished  consists  of  the  following 
basic  components: 

Содержание 22E

Страница 1: ...Wesrern Electric 22E SPEECH INPUT EQUIPMENT IN S T RUCT I O N BULLET I N N O 1175 I S S UE N O 1...

Страница 2: ...siern Electric 22E SPEECH INPUT EQUIPMENT Research and design by Bell Telephone Laboratories INSTRUCTION BULLETIN NO 1175 ISSUE NO I...

Страница 3: ...Equipment Furnished a AC Operation b Battery Operation c Both AC and Battery Operation 2 Accessories Required a Cables and Plugs b Batteries c Monitoring d Microphones and Microphone Accessories 3 As...

Страница 4: ...INDEX Cont d e Ground f Battery Cable g AC Connection h Power Switches i Plate Current Check 5 Operation a Gain Settings b Output Level c Precautions IV MAINTENANCE 6 6 7 7 7 7 7 7 7 7...

Страница 5: ...Case with Cover 0 Ballery compartment with cord nd plug E AC Power Unit with cord nd plug F 639 type Microphone G KS t2COO Transmiller Cover H 24A Tronsmiller Mounting I I IA Trans mitter Allochment J...

Страница 6: ...lines 65 db for Battery Operation Both at 70 db net gain and referred to output 62 db for AC Operation signal of 18 dbm Approximately 0 2 J o at 8 dbm 1 5 at 18 dbm See curve Figure 2 Four parallel mi...

Страница 7: ...sa as may be required Receptacles and parallel mixing potentiom eters are provided for four microphones A master gain control is incorporated in the 3 stage amplifier Pads for either 150 or 600 ohm ou...

Страница 8: ...rmally used for most program lines but the 150 ohm output is frequently used where the mismatch will provide a beneficial equalizing effect tending to compensate for the frequency transmission charact...

Страница 9: ...ier A 47 Type Plug and a cord such as the 630 Type are recommended for making con nections between the 22E Amplifier and the monitoring amplifier ES 610199 Power Unit For a c operation the ES 610199 P...

Страница 10: ...rage battery operation the required batteries are 4 Eveready No 762S or Burgess No 5308 for plate 1 Exide No 3 AC 7 1 storage battery per DA 26588 For filaments For dry cell battery operation the requ...

Страница 11: ...wer Unit or both The B 147071 Set of Accessories for bat tery operation contains all the accessories excepting batteries listed above that are 6 necessary to modify the carrying case Full instructions...

Страница 12: ...ould be permit ted however to allow for variations in sound levels of the program Output Level Normally an output level of 8 vu is ade quate In some cases jt may be necessary to transmit programs at a...

Страница 13: ...as This enamel may be obtained from the nearest distributor of Western Electric audio facili ties It is supplied with an aluminum powder 8 that is not required for this application Should the 22E Spee...

Страница 14: ...es one round and one hexagonal mounting nuts P R Mallory Co 1321 Two Gang Switch Two Circuits 11 Points each Circuit with Shaft IA lg 2 Plain Hex Nuts and 1 Lockwasher Yaxley Manufacturing Co Switch S...

Страница 15: ...rying Case per ESR 610264 2 Following Items are Specific to the type of Power Supply For AC Supply Mallory Capacitor 10 10 mf 450 V Type FPO 231 1 dia x 2 lg can Furnish with metal washer A 93403 Mall...

Страница 16: ..._ 2 3 4 5 67891 20 100 fRlQU NC IN CYCLES PU SlCO D Fig 1 Frequency Response Curve NOTE 7 500 C l S 2 NO H uM ONLY LINE VOlTAGf 120V 60 CYCU A C 2 OUTPUT LEVEL 18 DBM I I I I I I III OUTPUT LEVEL e DB...

Страница 17: ...F C5 0 4MF R2 62QW R3 24QOW C4 0 4MF C 7 0 03MF Rl3 0 24MEG cs 50MF Rl2 s I 620W C6 1 I R2S I I 2 MF r 51ooow DI 5 4 3 I I 2 I T2 17SB I RD RD WH 3 Rl4 Rl5 3300W 2400 I I 0 1 __ e 14 QOFF O OFIL I I 0...

Страница 18: ...l 5 CNO OR J Cl I I I I I I 0 c t _ _ I OA L T L d ll l T IT I IleL AO Ct I C7 i j I c wH I I WH rl u I l 1 f 1 l I I I 1 9 i I C2 k t N l I T 0 03 t O 4 I T2 ____ _ l l L 1 ___ c I 0 c r 1 I 11 V I I...

Страница 19: ...Tl JI LI L2 llOV A C CORD ANO PLUG TO AMPLIFIER CONTROL UNIT Fig S Power Unit Schematic AC FIL PLATE DC 3 J2 03 4j 06J2 DC...

Страница 20: ...v suu r y l D c 0 c liLJ r I RD I I I I I I I I L2 I ______ I _ I I I I I I I I I I LI I __ _ __ _ I GROUND i t i 1 IU W til JI I I I 110 O f VSI F F f __ II II 01 r I 2 4n 1 5 7_ 6 O Tl 0 100 n II a...

Страница 21: ...wesrern Electric QUALITY COUNTS...

Отзывы: