![Western Digital Ultrastar DC HC310 Скачать руководство пользователя страница 244](http://html1.mh-extra.com/html/western-digital/ultrastar-dc-hc310/ultrastar-dc-hc310_specifications_961649244.webp)
230
Western Digital Hard Disk Drive OEM Specification
11.37.4
Sanitize Status Ext Command (feature: 0000h)
Com m and Block Output Registers
Com m and Block Input Registers
Register
7
6
5
4
3
2
1
0
Register
7
6
5
4
3
2
1
0
Data Low
-
-
-
-
-
-
-
-
Data Low
-
-
-
-
-
-
-
-
Data High
-
-
-
-
-
-
-
-
Data High
-
-
-
-
-
-
-
-
Feature
Current
0
0
0
0
0
0
0
0
Error
...See Below ...
Previous
0
0
0
0
0
0
0
0
Sector Count
Current
-
-
-
-
-
-
-
V
Sector Count
HOB=0
-
-
-
-
-
-
-
-
Previous
-
-
-
-
-
-
-
-
HOB=1
V
V
V
-
-
-
-
-
Sector Number
Current
-
-
-
-
-
-
-
-
Sector Number
HOB=0
V
V
V
V
V
V
V
V
Previous
-
-
-
-
-
-
-
-
HOB=1
-
-
-
-
-
-
-
-
Cylinder Low
Current
-
-
-
-
-
-
-
-
Cylinder Low
HOB=0
V
V
V
V
V
V
V
V
Previous
-
-
-
-
-
-
-
-
HOB=1
-
-
-
-
-
-
-
-
Cylinder High
Current
-
-
-
-
-
-
-
-
Cylinder High
HOB=0
-
-
-
-
-
-
-
-
Previous
-
-
-
-
-
-
-
-
HOB=1
-
-
-
-
-
-
-
-
Device/Head
1
1
1
D
-
-
-
-
Device/Head
-
-
-
-
-
-
-
-
Command
1
0
1
1
0
1
0
1
Status
...See Below ...
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC
UNC
0
IDN
0
ABT
T0N
AMN
BSY
RDY
DF
DSC
DRQ
COR
IDX
ERR
V
Vs
0
V
0
V
0
0
0
V
0
V
-
0
-
V
Table 199 Sanitize Status Ext Command (B4h/0000h)
The SANITIZE STATUS EXT command returns information about current or previously completed sanitizes
operations. This includes:
a)
progress indication on a current sanitize operation
b)
whether a previous sanitize operation completed successfully or unsuccessfully
c)
if an unsupported sanitize device command was received.
The SANITIZE STATUS EXT command is valid in every state of the Sanitize Device state machine.
Output Parameters To The Device
Sector Count Current bit 0
CLEAR SANITIZE OPERATION FAILED
If Sanitize Device state machine is in the SD3: Sanitize Failed state:
a)
the FAILURE MODE bit was set to one in the Sanitize Device command
that caused the sanitize operation
b)
the sanitize operation failed
c)
the CLEAR SANITIZE OPERATION FAILED bit is set to one in the
SANITIZE STATUS EXT command then the Sanitize Device state machine
transitions to the SD0: Sanitize Idle state.
If the CLEAR SANITIZE OPERATION FAILED bit is set to one in the SANITIZE
STATUS EXT command, and the FAILURE MODE bit was set to zero in the
Sanitize Device command that caused the sanitize operation, the SANITIZE
STATUS EXT command returns command aborted.