10
Installation Instructions
Energy Level
Capacity Code
Indoor Unit
07
23
09
26
12
35
18
52
24
71
Outdoor Unit
18
52
24
71
28
82
>
2000
>
500
2. During the transportation of the outdoor unit, two lifting ropes long enough must be used
in four directions and the separation included angle must be less than 40° prevent the
center of unit deviating.
3. During the installation, M10 screws should be used to fix the support leg and base frame
of the unit.
4. The unit should be installed on a concrete base frame with a height of 10cm.
5. The installation space of the unit should be as required in Fig.7.
Installation Space Requirements of the Outdoor Unit:
>
500
>
500
>
2000
>
1000
>
500
Units: mm
Fig.7
Connection between Indoor and Outdoor Units
● Wiring of the Power Cord
CAUTION!
A breaker must be installed, capable of cutting off the power supply for the whole system.
1. Open the side plate.
2. Connect the power card to
the terminals “ L ”, “ N ” and also the earthing bolt, and
then connect the wring terminals “ N(1) , 2 , 3 ”of the indoor unit to those of the outdoor
unit correspondingly.
3. Fix the power cord with wire clips.
● Energy level and Capacity Code of the Indoor and Outdoor Units
Table 4