RT-310 / RT-320 User Guide
Page 28 (30)
5.2.2 Factory Reset Procedure
The Factory Reset is performed with a factory reset adapter that is connected to one of the Ethernet ports during
the start-up.
Step
Description
1.
Plug the factory reset adapter to one of the Ethernet interfaces.
2.
Power the device
3.
Wait until factory reset adapter is detected. This is indicated by an ORANGE operation LED in
combination with a RED status LED
4.
Remove factory reset adapter within 15 seconds
5.
A successful initiation of a factory Reset is indicated by an ORANGE BLINKING operation LED in
combination with a RED BLINKING failure LED
Table 24 Factory reset procedure
After successful factory reset, the dust cap must be closed to ensure the IP requirements.