background image

 

V3.8 

 

 

OnTime Industrial Ethernet 

 

U/R/T200 series Installation Guide 

 

 

- 1 -

 

 

 
 
 
 
 
 
 
 
 
 

 

 
 
 

U/R/T200 series Installation Guide 

 

 
 
 
 
 
 
 
 

 ..............................................................................................................................................  

Содержание R200 series

Страница 1: ...V3 8 OnTime Industrial Ethernet U R T200 series Installation Guide 1 U R T200 series Installation Guide ...

Страница 2: ...V3 8 OnTime Industrial Ethernet U R T200 series Installation Guide 2 ...

Страница 3: ... FRONT PANEL LED S AND PUSH BUTTONS 14 3 3 1 Manual Configuration 14 3 3 2 Normal Indication Mode 15 3 3 3 Select Port Mode 15 3 3 4 Speed Button 15 3 3 5 Duplex Button 15 3 3 6 Auto negotiation 15 3 3 7 Save Button 15 3 3 8 LED Fault indication 16 3 4 FIBER OPTIC CARE 17 4 IP CONFIGURATION SOFTWARE 18 4 1 FRNT VERSION 0 SINGLE RING 23 4 2 FRNT VERSION 1 MULTIPLE RINGS 24 4 3 RSTP STP 25 4 4 SNMP ...

Страница 4: ...35 8 2 FTP SERVER CONFIGURATION 35 8 2 1 Stopping existing FTP servers 35 8 2 2 Configure the FTP server 35 8 3 FIRMWARE UPGRADE VIA IP CONFIGURATION TOOL 37 8 4 FTP SERVER TROUBLESHOOTING 38 8 4 1 Example 1 38 8 4 2 Example 2 40 8 4 3 Typical problems 41 9 SOFTWARE VERSIONS OF THE R T200 SWITCH 42 9 1 INTRODUCTION 42 9 2 HOW TO UPGRADE FROM OLD TO NEW MAJOR SOFTWARE VERSION 42 9 3 IP CONFIGURATIO...

Страница 5: ...es Note Using the time synchronization SNMP IGMP snooping VLAN and MAC security management features of the T200 series require minimum network knowledge by the user 1 2 R200 The R200 series contains the same features as the T200 series except for time synchronization All chapters in this document except chapters 5 and 6 are relevant for the R200 series Note Using the SNMP IGMP snooping VLAN and MA...

Страница 6: ...ting power and port connections A quick guide for how to install a U R T 200 using DIN rail mounting default is as follows 1 Mounting see chapter 3 1 1 2 Power connection see chapter 3 1 5 3 Port connections see chapter 3 1 6 and 3 1 7 Now the switch is ready for use 2 1 3 Redundant ring FRNT0 configuration Setting up several R T200 switches in a redundant ring using the FRNT0 protocol requires sw...

Страница 7: ...or recovery when a connection between the switches is broken To set up a FRNT v0 configuration the following steps must be followed 1 Define which Switch that shall be the network Focal Point 2 Power up the switch and connect this to the network 3 Assign an IP address for the configuration software Ensure the address range is within the same Subnet as your assigned IP address for your PC 4 Press t...

Страница 8: ...itch The Switch will run through the start sequence During this period communication to the Switch will be lost 12 Connect the next Switch into the ring This must be connected from Port 8 to Port 7 in a clockwise manner on version 2 30 or older 13 Press the Scan for devices button The second Switch will appear on the list 14 Run the cursor over the second Switch and left click the mouse 15 If requ...

Страница 9: ... vertical and horizontal mounting is possible The DIN rail kit contains the following parts 2 x DIN clips 4 x screws Figure 1 shows vertical and horizontal DIN rail mounting Figure 1 DIN rail mounting Detailed drawings for both vertical MOUN0004 and horizontal MOUN0002 DIN rail mounting are found on http www OnTimenet com downloads htm Heavy duty DIN clips are also available improved vibration pro...

Страница 10: ...it MOUN0009 contains the following parts 2 x short angle brackets 4 x nut brackets 2 x H lists 4 x curved nuts 4 x rack screws 4 x rack brackets 8 x brackets 8 x screws Figure 2 shows how to mount two URT200 by using the 19 dual units mounting kit This mounting kit must be ordered separately Figure 2 19 dual units mounting kit ...

Страница 11: ...N0008 contains the following parts 1 x long angle bracket 1 x short angle bracket 4 x nut brackets 4 x curved nuts 4 x rack screws 4 x rack brackets 8 x brackets 8 x screws Figure 3 shows how to mount on U R T200 by using the 19 single unit mounting kit This mounting kit must be ordered separately Figure 3 19 single unit mounting kit ...

Страница 12: ...1 4 Wall mounting The U R T200 wall mounting kit MOUN0006 contains the following parts 2 x short angle brackets 4 x nut brackets 8 x brackets 8 x screws Figure 4 shows how to mount the wall mounting kit This mounting kit must be ordered separately Figure 4 Wall mounting kit ...

Страница 13: ... switches or the switch and a fiber enabled end node Manual swaping of the TX RX drop link on one of the fiber devices is required in case the LED is off on both devices This can be done either directly on the switch fiber port or on a fiber patch panel if this is available preferably 3 2 Power Supply Connector 3 2 1 Redundant power inputs The switch is designed to operate permanently over a very ...

Страница 14: ...Supply Failure Focal Point Redundancy Mode activated Time sync error NMEA reports or PPS missing on RS232 422 interface Using the Switch configuration software the fault contact can highlight the following addition failures Link Port 1 to Port 8 Failure The user can connect to the fault contact STAT pin on power connector see Figure 6 with a pull up resistor to Vin The fault contact implementation...

Страница 15: ...w available Each additional port can be placed into Manual mode by subsequent pressing of the Select Port button If no buttons are pressed for 30 seconds the unit will return back to Normal Indication Mode 3 3 4 Speed Button Pressing the Speed button once selects 10M twice enables 100M 3 3 5 Duplex Button Pressing the Duplex button changes the Port duplex mode from full duplex to half duplex and v...

Страница 16: ...ll blink in case of a port alarm Relevant in case port alarm is enabled in the IP configuration tool 100 LED will blink in case of no PPS signal or no NMEA reports from the GPS receiver is received on the GPS interface Relevant when time synchronization and external time base are enabled in the IP configuration tool The 100 LED will also blink in case the SNTP client is out of synchronization rele...

Страница 17: ...eiver components may be the result of just a small invisible piece of dust The fiber optic transceivers and associated patch cables must be treated with great care Therefore the following rules should be adhered to during any commissioning work and fiber optic installation Dust caps must be replaced immediately after removal of patch cable from transceiver or patch box Failure to comply could resu...

Страница 18: ...mputer the application is called IP configuration Start the application from a PC on the network Make sure that the IP Address of the configuration software see figure below is in the same sub domain as your PC Figure 9 By clicking the Scan for switches button the IP Configuration Software will detect the switches in the IP subnet The information in the figure below will appear for each switch IP ...

Страница 19: ...tallation Guide 19 Figure 10 By clicking on the line for each respective switch further configuration opportunities will appear See below Figure 11 First Switch Found Switch IP Address Switch MAC Address Firmware Revision Configuration Style Ring Status ...

Страница 20: ...he ring should be broken the Status of the Focal Point switch will change from RING to BUS An exclamation mark will be shown on the ports that have lost connection Figure 13 Scanning For Devices Highlights All Switches On Ring Highlights FP Running Network As A Ring Highlights Network Focal Point Switch software version Scanning For Devices Highlights All Switches On Ring Ring Failure Occurred FP ...

Страница 21: ... appear see Figure 14 Redundant connection between two FRNT v0 rings FRNT v1 can be configured here See chapter 4 2 for further information of FRNT v1 Figure 14 FRNT v1 Multiple ring configuration By clicking the port config button in the Port configuration setup dialog box will appear see Figure 15 See chapter 4 10 for more details Figure 15 Port configuration setup ...

Страница 22: ...tallation Guide 22 By clicking the VLAN button in the VLAN configuration setup dialog box will appear see Figure 16 The VLAN tick box must be enabled before the VLAN button is enabled See chapter 4 12 for more details Figure 16 VLAN configuration setup ...

Страница 23: ...27 Press the Set button to assign this IP address and Subnet settings to the Switch 28 Tick the Enable FRNT Ring and Network focal point to set the Switch to be the Focal Point and Bus Member to ensure the Switch configured to run within a Redundant Ring 29 Press the Set button all your changes performed will be set 30 Press the Restart button to re configure the Switch The Switch will run through...

Страница 24: ...s a FRNT primary switch through the advanced dialog box in the IP configuration tool by ticking the Enable redundant bridge function and FRNT primary switch see 3 Define which port that will act as the FRNT enabled port in the advanced dialog box Connect this to the other FRNT v0 ring 4 Choose one of the switches in the same FRNT v0 ring to be the FRNT secondary switch in IP configuration tool 5 T...

Страница 25: ...e must be shown if the switch is used in a topology with network loops and where some of the ports are disabled for RSTP STP Note RTSP STP and FRNT can not be combined 4 4 SNMP The R T200 switch supports Simple Network Management Protocol SNMP To enable disable SNMP tick the SNMP box and press the Set button Press the Reset button to restart the Switch with SNMP enabled disabled The R T200 MIBs MI...

Страница 26: ...s The private MIB is available for download from OnTime web page http www OnTimenet com upgrade htm or the CD This MIB can be imported in the users Network Management Tool See the documentation for your Network Management Tool for how to import and how to use a private MIB 4 5 DHCP The R T200 switch supports Dynamic Host Configuration Protocol DHCP The R T200 switch can get an IP address dynamical...

Страница 27: ...nabling Push buttons The front panel push buttons on the switch can be enabled disabled in the IP configuration tool The push buttons are by default enabled an operator at the switch installation can change the speed duplex connectivity and auto negotiation settings per port To enable disable push buttons tick the Enable front panel push buttons and press the Set button Press the Reset button to r...

Страница 28: ...default IGMP settings Auto mode enabled Querier disabled same operation as above but the switch cannot act as an IGMP Querier Auto mode disabled Querier enabled the switch will always act as an IGMP Querier Each switch router will act as IGMP Querier if this configuration is used on each switch router in the network The interval between two IGMP query packets can also be set in the IP configuratio...

Страница 29: ...or IP configuration must always use the white VLAN in order to communicate with the switch CPUs Thus the switch CPUs can always be accessed via port 1 with untagged packets since port 1 has the white VLAN as the default VLAN Press the Set button after any changes performed on the VLAN parameters in the VLAN configuration dialog while a switch restart is required in case the VLAN tick box is change...

Страница 30: ... IEEE1588 Transparency A T200 switch should be enabled for IEEE1588 Transparency if this switch is not acting as a IEEE1588 Grand Master A IEEE1588 Transparency switch traps IEEE1588 packets that are sent and received between the IEEE1588 Grand Masters and Slaves The variable switch latency of the IEEE1588 SYNC and DEL_REQ through the Transparency switch are measured and the corresponding FOLLOW_U...

Страница 31: ...of TTL and pin 15 and 6 in case of RS 422 OUT 2 is available on the 15 pin time sync connector GPS interface on the T200 front panel OUT 2 is pin 3 and 7 ground in case of TTL and pin 13 and 8 in case of RS 422 5 6 Pulse Per Minute A Pulse Per Minute PPM output signal will be generated on the STAT pin on the power connector if the Pulse Per Minute tick box is enabled This option will disable other...

Страница 32: ...om GPS 3 PPX OUT2 TTL OUT2 PPX output TTL signal 4 PPS RS 422 RX Pulse per second input from GPS RS 422 I F 5 PPS TTL INPUT Pulse per second input from GPS TTL level 6 PPX OUT1 TX OUT1 PPX RS 422 negative transmitter output 7 PPX TTL 0V Return path for RS232 and TTL signals 8 PPX OUT2 TX OUT2 PPX RS 422 negative transmitter output 9 PPX OUT1 TTL OUT1 PPX output TTL signal 10 RS232 TTL 0V Return pa...

Страница 33: ...from Trimble and must be ordered separately from Deutsch Commercial Products 5733 W Whittier Avenue Hemet California 92545 Phone 909 765 2200 Fax 909 922 1544 Or Westermo OnTime networks provide cables that are pre assembled in the Acutime end and that is sealed and sufficient for outdoor installations The following standard cable lengths are available 15 30 60 and 120 m Cable length specification...

Страница 34: ...2 can be connected on the same serial interface according to the RS 422 standard The RS 422 serial interface has the following configuration Baudrate 9600 Data bit 8 Stop bit 1 Parity No The connector type for the T208 switch is the same as for the GPS receiver 15 pol high density D sub type connector female part on the switch and male part on cable assembly The RS 422 interface shall always be te...

Страница 35: ...iguration tool 8 2 FTP server configuration 8 2 1 Stopping existing FTP servers Only one FTP server can run on the machine at the same time make sure to stop any other FTP servers Windows 2000 and XP This is done by right clicking on My Computer Manage Services and Applications Services Find the FTP Service in the service list right click on it and choose stop Other Windows versions Find the Servi...

Страница 36: ...0 series Installation Guide 36 3 Type in User Name anonymous Set Home directory to C see figure below 4 Click done 5 Go to Security General see figure below 6 Fill in the dialog box as shown below 7 Go to Logging Log Options see figure below ...

Страница 37: ...Windows can alter the first letter if Word is set as editor for your PC the first letter will therefore have to be altered to lower case again manually in the Host name field 5 Type the name of the bin file in the Location field 6 Click Set 7 A progress bar will appear in the bottom of the dialog box and the switches will restart Note Make sure that you have waited at least 3 minutes after the upg...

Страница 38: ...mo OnTime switch The FTP server must allow anonymous logins The best way to test the FTP server itself is to run an FTP client session on the same PC 8 4 1 Example 1 Upgrading from image version 2 35 or 2 38 and higher version numbers beta versions 9 66 and above C ftp 192 168 13 101 Connected to 192 168 13 101 220 WFTPD 2 0 service by Texas Imperial Software ready for new user User 192 168 13 101...

Страница 39: ...ted 01 14 05 10 50 17 Anonymous user anonymous logged in pass idt OnTimenet com 01 14 05 10 50 17 User anonymous logged in 01 14 05 10 50 21 Command TYPE I received 01 14 05 10 50 21 TYPE set to I N 01 14 05 10 50 26 Command PORT 192 168 13 101 5 13 received 01 14 05 10 50 26 PORT set to 192 168 13 101 1293 5 13 01 14 05 10 50 26 Command RETR vx304 bin received 01 14 05 10 50 26 RETR failed file d...

Страница 40: ... PORT command okay 150 C vx304 bin file ready to send 2487164 bytes in IMAGE Binary mode 226 Transfer finished successfully ftp 2487164 bytes received in 0 06Seconds 40773 18Kbytes sec ftp bye 221 Windows FTP Server WFTPD by Texas Imperial Software says goodbye C With a corresponding FTP server log 01 14 05 10 56 17 Connection accepted from 192 168 13 101 01 14 05 10 56 20 Command USER anonymous r...

Страница 41: ... not have to inspect the log from the FTP server 8 4 3 Typical problems FTP server not running Anonymous logins not allowed Image file does not exist in the home directory first example or root directory second example Root directory access not allowed second example If you can not succeed in performing these examples there is no point trying to upgrade the image on the Westermo OnTime switch It w...

Страница 42: ...new major software version Chapter 8 describes how to upgrade an R T200 switch A switch software upgrade shall preferably be performed on a switch that is removed from the network However software upgrade on a switch in a running network is possible The principles are based on FTP download of the new image via FTP then the switch will isolate itself from the network write the new software image to...

Страница 43: ... SWITCH FOCAL POINT SWITCH MEMBER SWITCH TX FX Step 2 FOCAL POINT SWITCH MEMBER SWITCH MEMBER SWITCH MEMBER SWITCH FOCAL POINT SWITCH TX FX Step 1 FOCAL POINT SWITCH MEMBER SWITCH FX MEMBER SWITCH MEMBER SWITCH Step 4 FOCAL POINT SWITCH MEMBER SWITCH FOCAL POINT SWITCH MEMBER SWITCH TX FX MEMBER SWITCH Step 3 ...

Страница 44: ...tware version running on the switch This means that no separate release note exist for a new version of the IP configuration tool How to use the IP configuration tool is described in this document Old software versions of the IP configuration tool can be used versus R T200 switches with new features not supported in the IP configuration tool However the user will then not be able to configure the ...