161
6623-3201
Timeout before sending
The timeout allows data accumulated by the framer to be sent
after a specified period of serial receive inactivity. This pre-
vents data from being held in the framer indefinitely should no
more data arrive on the serial port. The timeout is set in 100
millisecond units, so, for example, a one second timeout would
be set as a value of 10.
Immediate send character matching
This field allows the framer to be configured so that if certain
characters are received the accumulated data is immediately
sent. The character matching can function in two modes:
Match any character
If either of the characters set the in Match characters field are
received, the data will be sent immediately.
Match all characters
If both of the characters set in the Match characters field are
received in order, the data will be sent immediately.
Match characters
Used in conjunction with the Immediate send character
matching field, these characters determine what data will
cause an immediate send. The values are entered as a hex
value, so, for example, a newline (ASCII 10) would be entered
as 0A. To delete a value, clear the text in the field.
Characters to wait after match
Used in conjunction with the Immediate send character
matching field, this count determines how many additional
characters will be received after an immediate match charac-
ter is detected. This is useful if some trailing characters always
follow the match character.
Содержание MRD-310
Страница 11: ...11 6623 3201 Figure 9 Status alarm page ...
Страница 51: ...51 6623 3201 Figure 43 SMS Triggers configuration page ...
Страница 55: ...55 6623 3201 Figure 46 SMS Triggers number to accept added ...
Страница 125: ...125 6623 3201 Figure 93 IPsec Phase 2 configuration ...
Страница 137: ...137 6623 3201 Figure 100 IPsec connection status Figure 101 IPsec connection status detail ...