48
Duplex(10 Half), 100M Full Duplex(100 Full) and 100M Half Duplex(100 Half).
Gigabit Ethernet Port: AutoNegotiation, 10M Full Duplex(10 Full), 10M Half
Duplex(10 Half), 100M Full Duplex(100 Full), 100M Half Duplex(100 Half), 1000M
Full Duplex(1000 Full), 1000M Half Duplex(1000 Half).
The default mode is Auto Negotiation mode.
In
Flow Control
column, “Symmetric” means that you need to activate the flow
control function of the remote network device in order to let the flow control of
that corresponding port on the switch to work. “Disable” means that you don’t
need to activate the flow control function of the remote network device, as the
flow control of that corresponding port on the switch will work anyway.
Once you finish configuring the settings, click on
Apply
to save the configuration.
Technical Tips:
If both ends are not at the same speed, they can’t link with each
other. If both ends are not in the same duplex mode, they will be connected by
half mode.
4.3.2
Port Status
Port Status shows you current port status.
The switch supports SFP fiber transceiver with Digital Diagnostic Monitoring
(DDM) function that provides real time information of SFP transceiver and allows
user to diagnostic the optical fiber signal received and launched.
The information of SFP DDM will listing on another table.
The description of the columns is as below:
Port
: Port interface number.
Type
: 100TX -> Fast Ethernet port. 1000TX -> Gigabit Ethernet port.
Link
: Link status. Up -> Link UP. Down -> Link Down.
State
: Enable -> State is enabled. Disable -> The port is disable/shutdown.
Содержание MDI-112 Series
Страница 1: ...1 MDI 118 Series MDI 112 Series User s Manual Version 1 1 Industrial Managed Ethernet Switch...
Страница 9: ...5 Figure of MDI 118 F2G Figure of MDI 112 F4G...
Страница 102: ...98 After configuration press Apply to enable the settings...
Страница 143: ...139 Username admin Password admin SMTP Email Alert Receipt Receipt 1 support westermo se Receipt 2 Receipt 3 Receipt 4...
Страница 175: ...171...